Xenon-gas ionization chamber to improve particle identification of heavy ion beams with Z>70

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Yoshimoto, Masahiro, Fukuda, Naoki, Matsumura, Riku, Nishimura, Daiki, Otsu, Hideaki, Shimizu, Yohei, Sumikama, Toshiyuki, Suzuki, Hiroshi, Takahashi, Hiroyuki, Takeda, Hiroyuki, Tanaka, Junki, Yoshida, Koichi
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866913422404222976
author Yoshimoto, Masahiro
Fukuda, Naoki
Matsumura, Riku
Nishimura, Daiki
Otsu, Hideaki
Shimizu, Yohei
Sumikama, Toshiyuki
Suzuki, Hiroshi
Takahashi, Hiroyuki
Takeda, Hiroyuki
Tanaka, Junki
Yoshida, Koichi
author_facet Yoshimoto, Masahiro
Fukuda, Naoki
Matsumura, Riku
Nishimura, Daiki
Otsu, Hideaki
Shimizu, Yohei
Sumikama, Toshiyuki
Suzuki, Hiroshi
Takahashi, Hiroyuki
Takeda, Hiroyuki
Tanaka, Junki
Yoshida, Koichi
contents In conventional ionization chambers (ICs) using P-10 (Ar+CH4) gas, as the atomic number (Z) of the ion beams increases in the energy region of 200-300 MeV/u, the Z resolution deteriorates rapidly when Z>70. This degradation is attributed to substantial energy loss straggling caused by charge state fluctuation when the beams traverse a gas medium. The energy loss straggling increases when the beams cannot attain charge state equilibrium in the IC gas. In this study, a xenon-based gas (Xe+CH4), exhibiting a sufficiently large charge state changing cross section, was used in the IC to reach charge state equilibrium. The responses of ICs with P-10 and the xenon-based gases were examined using 238U beams and cocktail radioactive isotope (RI) beams with Z=40-90 at the RI Beam Factory (RIBF). For 238U beams at 165-344 MeV/u, the P-10 gas IC yielded an energy resolution of 1.9-3.0% in full width at half maximum (FWHM), which proved inadequate for Z identification in the uranium region. In contrast, the xenon-based gas IC demonstrated a satisfactory energy resolution of 1.4-1.6%. When using cocktail RI beams, a Z resolution of 1.28 and 0.74 was achieved by the P-10 and the xenon-based gas ICs, respectively, for beams with Z=84-88 at 200 MeV/u. The contrast in Z resolutions between the P-10 and the xenon-based gas ICs was effectively elucidated by the energy loss straggling model, incorporating collisional straggling and straggling due to charge state changes in the IC gases. The xenon-based gas IC, with more than 3sigma Z separation across a broad Z range (Z=40-90), emerged as a practical solution for Z identification of heavy ion beams.
format Preprint
id arxiv_https___arxiv_org_abs_2401_08679
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Xenon-gas ionization chamber to improve particle identification of heavy ion beams with Z>70
Yoshimoto, Masahiro
Fukuda, Naoki
Matsumura, Riku
Nishimura, Daiki
Otsu, Hideaki
Shimizu, Yohei
Sumikama, Toshiyuki
Suzuki, Hiroshi
Takahashi, Hiroyuki
Takeda, Hiroyuki
Tanaka, Junki
Yoshida, Koichi
Instrumentation and Detectors
High Energy Physics - Experiment
Nuclear Experiment
In conventional ionization chambers (ICs) using P-10 (Ar+CH4) gas, as the atomic number (Z) of the ion beams increases in the energy region of 200-300 MeV/u, the Z resolution deteriorates rapidly when Z>70. This degradation is attributed to substantial energy loss straggling caused by charge state fluctuation when the beams traverse a gas medium. The energy loss straggling increases when the beams cannot attain charge state equilibrium in the IC gas. In this study, a xenon-based gas (Xe+CH4), exhibiting a sufficiently large charge state changing cross section, was used in the IC to reach charge state equilibrium. The responses of ICs with P-10 and the xenon-based gases were examined using 238U beams and cocktail radioactive isotope (RI) beams with Z=40-90 at the RI Beam Factory (RIBF). For 238U beams at 165-344 MeV/u, the P-10 gas IC yielded an energy resolution of 1.9-3.0% in full width at half maximum (FWHM), which proved inadequate for Z identification in the uranium region. In contrast, the xenon-based gas IC demonstrated a satisfactory energy resolution of 1.4-1.6%. When using cocktail RI beams, a Z resolution of 1.28 and 0.74 was achieved by the P-10 and the xenon-based gas ICs, respectively, for beams with Z=84-88 at 200 MeV/u. The contrast in Z resolutions between the P-10 and the xenon-based gas ICs was effectively elucidated by the energy loss straggling model, incorporating collisional straggling and straggling due to charge state changes in the IC gases. The xenon-based gas IC, with more than 3sigma Z separation across a broad Z range (Z=40-90), emerged as a practical solution for Z identification of heavy ion beams.
title Xenon-gas ionization chamber to improve particle identification of heavy ion beams with Z>70
topic Instrumentation and Detectors
High Energy Physics - Experiment
Nuclear Experiment
url https://arxiv.org/abs/2401.08679