A gradient-based approach to fast and accurate head motion compensation in cone-beam CT

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Thies, Mareike, Wagner, Fabian, Maul, Noah, Yu, Haijun, Goldmann, Manuela, Schneider, Linda-Sophie, Gu, Mingxuan, Mei, Siyuan, Folle, Lukas, Preuhs, Alexander, Manhart, Michael, Maier, Andreas
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866912077475479552
author Thies, Mareike
Wagner, Fabian
Maul, Noah
Yu, Haijun
Goldmann, Manuela
Schneider, Linda-Sophie
Gu, Mingxuan
Mei, Siyuan
Folle, Lukas
Preuhs, Alexander
Manhart, Michael
Maier, Andreas
author_facet Thies, Mareike
Wagner, Fabian
Maul, Noah
Yu, Haijun
Goldmann, Manuela
Schneider, Linda-Sophie
Gu, Mingxuan
Mei, Siyuan
Folle, Lukas
Preuhs, Alexander
Manhart, Michael
Maier, Andreas
contents Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT into clinical workflows faces challenges, primarily linked to long scan duration resulting in patient motion during scanning and leading to image quality degradation in the reconstructed volumes. This paper introduces a novel approach to CBCT motion estimation using a gradient-based optimization algorithm, which leverages generalized derivatives of the backprojection operator for cone-beam CT geometries. Building on that, a fully differentiable target function is formulated which grades the quality of the current motion estimate in reconstruction space. We drastically accelerate motion estimation yielding a 19-fold speed-up compared to existing methods. Additionally, we investigate the architecture of networks used for quality metric regression and propose predicting voxel-wise quality maps, favoring autoencoder-like architectures over contracting ones. This modification improves gradient flow, leading to more accurate motion estimation. The presented method is evaluated through realistic experiments on head anatomy. It achieves a reduction in reprojection error from an initial average of 3mm to 0.61mm after motion compensation and consistently demonstrates superior performance compared to existing approaches. The analytic Jacobian for the backprojection operation, which is at the core of the proposed method, is made publicly available. In summary, this paper contributes to the advancement of CBCT integration into clinical workflows by proposing a robust motion estimation approach that enhances efficiency and accuracy, addressing critical challenges in time-sensitive scenarios.
format Preprint
id arxiv_https___arxiv_org_abs_2401_09283
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A gradient-based approach to fast and accurate head motion compensation in cone-beam CT
Thies, Mareike
Wagner, Fabian
Maul, Noah
Yu, Haijun
Goldmann, Manuela
Schneider, Linda-Sophie
Gu, Mingxuan
Mei, Siyuan
Folle, Lukas
Preuhs, Alexander
Manhart, Michael
Maier, Andreas
Image and Video Processing
Computer Vision and Pattern Recognition
Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT into clinical workflows faces challenges, primarily linked to long scan duration resulting in patient motion during scanning and leading to image quality degradation in the reconstructed volumes. This paper introduces a novel approach to CBCT motion estimation using a gradient-based optimization algorithm, which leverages generalized derivatives of the backprojection operator for cone-beam CT geometries. Building on that, a fully differentiable target function is formulated which grades the quality of the current motion estimate in reconstruction space. We drastically accelerate motion estimation yielding a 19-fold speed-up compared to existing methods. Additionally, we investigate the architecture of networks used for quality metric regression and propose predicting voxel-wise quality maps, favoring autoencoder-like architectures over contracting ones. This modification improves gradient flow, leading to more accurate motion estimation. The presented method is evaluated through realistic experiments on head anatomy. It achieves a reduction in reprojection error from an initial average of 3mm to 0.61mm after motion compensation and consistently demonstrates superior performance compared to existing approaches. The analytic Jacobian for the backprojection operation, which is at the core of the proposed method, is made publicly available. In summary, this paper contributes to the advancement of CBCT integration into clinical workflows by proposing a robust motion estimation approach that enhances efficiency and accuracy, addressing critical challenges in time-sensitive scenarios.
title A gradient-based approach to fast and accurate head motion compensation in cone-beam CT
topic Image and Video Processing
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2401.09283