A new hydrogen-filled Cherenkov detector for Kaon tagging at the NA62 experiment at CERN

Fuente: arXiv
Saved in:
Bibliographic Details
Main Author: Sanders, Jack
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866916096324403200
author Sanders, Jack
author_facet Sanders, Jack
contents The precision measurement of $K^{+} \rightarrow π^{+} ν\barν$ at the NA62 experiment requires a kaon identification detector to have a time resolution better than 100ps, at least 95% kaon identification efficiency, and a pion misidentification probability of less than $10^{-4}$. Since the start of NA62 data taking in 2016, kaon identification has been performed by a differential Cherenkov with achromatic ring focus (CEDAR) detector with a nitrogen gas radiator. A new CEDAR using hydrogen (CEDAR-H) as a radiator gas has been developed to reduce the material in the beamline, reducing the beam particle scattering within the detector. CEDAR-H was validated during a two-week test beam at CERN in 2022 and was approved by the NA62 collaboration for use in data taking from 2023. The test beam results, installation and commissioning in the NA62 beamline are reported.
format Preprint
id arxiv_https___arxiv_org_abs_2401_09876
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A new hydrogen-filled Cherenkov detector for Kaon tagging at the NA62 experiment at CERN
Sanders, Jack
High Energy Physics - Experiment
Instrumentation and Detectors
The precision measurement of $K^{+} \rightarrow π^{+} ν\barν$ at the NA62 experiment requires a kaon identification detector to have a time resolution better than 100ps, at least 95% kaon identification efficiency, and a pion misidentification probability of less than $10^{-4}$. Since the start of NA62 data taking in 2016, kaon identification has been performed by a differential Cherenkov with achromatic ring focus (CEDAR) detector with a nitrogen gas radiator. A new CEDAR using hydrogen (CEDAR-H) as a radiator gas has been developed to reduce the material in the beamline, reducing the beam particle scattering within the detector. CEDAR-H was validated during a two-week test beam at CERN in 2022 and was approved by the NA62 collaboration for use in data taking from 2023. The test beam results, installation and commissioning in the NA62 beamline are reported.
title A new hydrogen-filled Cherenkov detector for Kaon tagging at the NA62 experiment at CERN
topic High Energy Physics - Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2401.09876