An Efficient Algorithm Based on Wavelet Transform to Reduce Powerline Noise From Electrocardiograms

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Rodenas, Juan, Garcia, Manuel, Rieta, Jose J., Alcaraz, Raul
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866913200662904832
author Rodenas, Juan
Garcia, Manuel
Rieta, Jose J.
Alcaraz, Raul
author_facet Rodenas, Juan
Garcia, Manuel
Rieta, Jose J.
Alcaraz, Raul
contents Nowadays, the electrocardiogram (ECG) is still the most widely used signal for the diagnosis of cardiac pathologies. However, this recording is often disturbed by the powerline interference (PLI), its removal being mandatory to avoid misdiagnosis. Although a broad variety of methods have been proposed for that purpose, often they substantially alter the original signal morphology or are computationally expensive. Hence, the present work introduces a simple and efficient algorithm to suppress the PLI from the ECG. Briefly, the input signal is decomposed into four Wavelet levels and the resulting coefficients are thresholded to remove the PLI estimated from the TQ intervals. The denoised ECG signal is then reconstructed by computing the inverse Wavelet transform. The method has been validated making use of fifty 10-min length clean ECG segments obtained from the MIT BIH Normal Sinus Rhythm database, which were contaminated with a sinusoidal signal of 50 Hz and variable harmonic content. Comparing the original and denoised ECG signals through a signed correlation index, improvements between 10 - 72% have been observed with respect to common adaptive notch filtering, implemented for comparison. These results suggest that the proposed method is featured by an enhanced trade-off between noise reduction and signal morphology preservation.
format Preprint
id arxiv_https___arxiv_org_abs_2401_10694
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle An Efficient Algorithm Based on Wavelet Transform to Reduce Powerline Noise From Electrocardiograms
Rodenas, Juan
Garcia, Manuel
Rieta, Jose J.
Alcaraz, Raul
Signal Processing
Nowadays, the electrocardiogram (ECG) is still the most widely used signal for the diagnosis of cardiac pathologies. However, this recording is often disturbed by the powerline interference (PLI), its removal being mandatory to avoid misdiagnosis. Although a broad variety of methods have been proposed for that purpose, often they substantially alter the original signal morphology or are computationally expensive. Hence, the present work introduces a simple and efficient algorithm to suppress the PLI from the ECG. Briefly, the input signal is decomposed into four Wavelet levels and the resulting coefficients are thresholded to remove the PLI estimated from the TQ intervals. The denoised ECG signal is then reconstructed by computing the inverse Wavelet transform. The method has been validated making use of fifty 10-min length clean ECG segments obtained from the MIT BIH Normal Sinus Rhythm database, which were contaminated with a sinusoidal signal of 50 Hz and variable harmonic content. Comparing the original and denoised ECG signals through a signed correlation index, improvements between 10 - 72% have been observed with respect to common adaptive notch filtering, implemented for comparison. These results suggest that the proposed method is featured by an enhanced trade-off between noise reduction and signal morphology preservation.
title An Efficient Algorithm Based on Wavelet Transform to Reduce Powerline Noise From Electrocardiograms
topic Signal Processing
url https://arxiv.org/abs/2401.10694