Deep Learning-based Intraoperative MRI Reconstruction

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Ottesen, Jon André, Storas, Tryggve, Vatnehol, Svein Are Sirirud, Løvland, Grethe, Vik-Mo, Einar O., Schellhorn, Till, Skogen, Karoline, Larsson, Christopher, Bjørnerud, Atle, Groote-Eindbaas, Inge Rasmus, Caan, Matthan W. A.
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866916103427457024
author Ottesen, Jon André
Storas, Tryggve
Vatnehol, Svein Are Sirirud
Løvland, Grethe
Vik-Mo, Einar O.
Schellhorn, Till
Skogen, Karoline
Larsson, Christopher
Bjørnerud, Atle
Groote-Eindbaas, Inge Rasmus
Caan, Matthan W. A.
author_facet Ottesen, Jon André
Storas, Tryggve
Vatnehol, Svein Are Sirirud
Løvland, Grethe
Vik-Mo, Einar O.
Schellhorn, Till
Skogen, Karoline
Larsson, Christopher
Bjørnerud, Atle
Groote-Eindbaas, Inge Rasmus
Caan, Matthan W. A.
contents Purpose: To evaluate the quality of deep learning reconstruction for prospectively accelerated intraoperative magnetic resonance imaging (iMRI) during resective brain tumor surgery. Materials and Methods: Accelerated iMRI was performed during brain surgery using dual surface coils positioned around the area of resection. A deep learning (DL) model was trained on the fastMRI neuro dataset to mimic the data from the iMRI protocol. Evaluation was performed on imaging material from 40 patients imaged between 01.11.2021 - 01.06.2023 that underwent iMRI during tumor resection surgery. A comparative analysis was conducted between the conventional compressed sense (CS) method and the trained DL reconstruction method. Blinded evaluation of multiple image quality metrics was performed by two working neuro-radiologists and a working neurosurgeon on a 1 to 5 Likert scale (1=non diagnostic, 2=poor, 3=acceptable, 4=good, 5=excellent), and the favored reconstruction variant. Results: The DL reconstruction was strongly favored or favored over the CS reconstruction for 33/40, 39/40, and 8/40 of cases for reader 1, 2, and 3, respectively. Two of three readers consistently assigned higher ratings for the DL reconstructions, and the DL reconstructions had a higher score than their respective CS counterparts for 72%, 72%, and 14% of the cases for reader 1, 2, and 3, respectively. Still, the DL reconstructions exhibited shortcomings such as a striping artifact and reduced signal. Conclusion: DL shows promise to allow for high-quality reconstructions of intraoperative MRI with equal to or improved perceived spatial resolution, signal-to-noise ratio, diagnostic confidence, diagnostic conspicuity, and spatial resolution compared to compressed sense.
format Preprint
id arxiv_https___arxiv_org_abs_2401_12771
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Deep Learning-based Intraoperative MRI Reconstruction
Ottesen, Jon André
Storas, Tryggve
Vatnehol, Svein Are Sirirud
Løvland, Grethe
Vik-Mo, Einar O.
Schellhorn, Till
Skogen, Karoline
Larsson, Christopher
Bjørnerud, Atle
Groote-Eindbaas, Inge Rasmus
Caan, Matthan W. A.
Image and Video Processing
Artificial Intelligence
Medical Physics
Purpose: To evaluate the quality of deep learning reconstruction for prospectively accelerated intraoperative magnetic resonance imaging (iMRI) during resective brain tumor surgery. Materials and Methods: Accelerated iMRI was performed during brain surgery using dual surface coils positioned around the area of resection. A deep learning (DL) model was trained on the fastMRI neuro dataset to mimic the data from the iMRI protocol. Evaluation was performed on imaging material from 40 patients imaged between 01.11.2021 - 01.06.2023 that underwent iMRI during tumor resection surgery. A comparative analysis was conducted between the conventional compressed sense (CS) method and the trained DL reconstruction method. Blinded evaluation of multiple image quality metrics was performed by two working neuro-radiologists and a working neurosurgeon on a 1 to 5 Likert scale (1=non diagnostic, 2=poor, 3=acceptable, 4=good, 5=excellent), and the favored reconstruction variant. Results: The DL reconstruction was strongly favored or favored over the CS reconstruction for 33/40, 39/40, and 8/40 of cases for reader 1, 2, and 3, respectively. Two of three readers consistently assigned higher ratings for the DL reconstructions, and the DL reconstructions had a higher score than their respective CS counterparts for 72%, 72%, and 14% of the cases for reader 1, 2, and 3, respectively. Still, the DL reconstructions exhibited shortcomings such as a striping artifact and reduced signal. Conclusion: DL shows promise to allow for high-quality reconstructions of intraoperative MRI with equal to or improved perceived spatial resolution, signal-to-noise ratio, diagnostic confidence, diagnostic conspicuity, and spatial resolution compared to compressed sense.
title Deep Learning-based Intraoperative MRI Reconstruction
topic Image and Video Processing
Artificial Intelligence
Medical Physics
url https://arxiv.org/abs/2401.12771