Characterization of the BOLDPET optical prototype, an innovative Cherenkov detector for 511 keV $γ$ radiation

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Chyzh, Roman, Tauzin, Gerard, Yvon, Dominique, Sung, Chi-Hsun, Breton, Dominique, Maalmi, Jihane, Schäfers, Klaus, Weinheimer, Christian, Sharyy, Viatcheslav
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909237490221056
author Chyzh, Roman
Tauzin, Gerard
Yvon, Dominique
Sung, Chi-Hsun
Breton, Dominique
Maalmi, Jihane
Schäfers, Klaus
Weinheimer, Christian
Sharyy, Viatcheslav
author_facet Chyzh, Roman
Tauzin, Gerard
Yvon, Dominique
Sung, Chi-Hsun
Breton, Dominique
Maalmi, Jihane
Schäfers, Klaus
Weinheimer, Christian
Sharyy, Viatcheslav
contents In the present work we describe the design, construction, and testing of the optical prototype developed for the BOLDPET project, with the objective of creating a PET detection module with high spatial and time resolution. The BOLDPET technology uses an innovative detection liquid, trimethylbismuth, for detecting 511 keV $γ$-quanta resulting from positron annihilation. The optical signal is exclusively produced through the Cherenkov mechanism, and the produced photons are detected using Planacon microchannel-plate photomultiplier. We achieve an excellent time resolution of 150 ps (FWHM) within a sizable detection volume measuring 55 mm x 55 mm x 25 mm. Through detailed Geant4 simulations, we examine the limiting factors affecting time resolution and explore potential avenues for improvement. Furthermore, we demonstrate the feasibility of coarse 2D localization of interactions using the optical signal alone, achieving a precision of about 5-8 mm (FWHM) within the homogeneous detection volume.
format Preprint
id arxiv_https___arxiv_org_abs_2401_17003
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Characterization of the BOLDPET optical prototype, an innovative Cherenkov detector for 511 keV $γ$ radiation
Chyzh, Roman
Tauzin, Gerard
Yvon, Dominique
Sung, Chi-Hsun
Breton, Dominique
Maalmi, Jihane
Schäfers, Klaus
Weinheimer, Christian
Sharyy, Viatcheslav
Instrumentation and Detectors
Medical Physics
In the present work we describe the design, construction, and testing of the optical prototype developed for the BOLDPET project, with the objective of creating a PET detection module with high spatial and time resolution. The BOLDPET technology uses an innovative detection liquid, trimethylbismuth, for detecting 511 keV $γ$-quanta resulting from positron annihilation. The optical signal is exclusively produced through the Cherenkov mechanism, and the produced photons are detected using Planacon microchannel-plate photomultiplier. We achieve an excellent time resolution of 150 ps (FWHM) within a sizable detection volume measuring 55 mm x 55 mm x 25 mm. Through detailed Geant4 simulations, we examine the limiting factors affecting time resolution and explore potential avenues for improvement. Furthermore, we demonstrate the feasibility of coarse 2D localization of interactions using the optical signal alone, achieving a precision of about 5-8 mm (FWHM) within the homogeneous detection volume.
title Characterization of the BOLDPET optical prototype, an innovative Cherenkov detector for 511 keV $γ$ radiation
topic Instrumentation and Detectors
Medical Physics
url https://arxiv.org/abs/2401.17003