Study of Applicability of Simple Closed Loop Input Impedance Model for Grid-Tie Inverters

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Santamargarita, Daniel, Huerta, Francisco, Sanz, Marina, Lazaro, Antonio, DArco, Salvatore, Sanchez, Santiago, Tedeschi, Elisabetta, Roldan, Javier
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917578250649600
author Santamargarita, Daniel
Huerta, Francisco
Sanz, Marina
Lazaro, Antonio
DArco, Salvatore
Sanchez, Santiago
Tedeschi, Elisabetta
Roldan, Javier
author_facet Santamargarita, Daniel
Huerta, Francisco
Sanz, Marina
Lazaro, Antonio
DArco, Salvatore
Sanchez, Santiago
Tedeschi, Elisabetta
Roldan, Javier
contents In recent years the need for DC distribution buses has increased considerably. As it can be noticed in the transport for example the distribution systems of the more electric aircrafts, ships, or electric cars. Given the complexities of the systems presented above, the need to use more and more switched power converters has arisen. The main problem of the connection of multiple controlled switched converters acting as source and load is the degradation of stability that occurs on the DC distribution bus due to the converter interactions. To study the stability in the distribution bus there are some wellestablished criteria. These criteria require knowledge of the input impedance of the converters that act as load and the output impedance of the equipment that acts as source. In order to reduce the complexity of obtaining the input impedance a model based on a controlled converter acting as a constant power load (CPL) is commonly used. This article studies the accuracy of this model for a commonly used topology in distribution systems nowadays, Two Level Voltage Source Converter (2L-VSC), studying different scenarios that make the model become inaccurate.
format Preprint
id arxiv_https___arxiv_org_abs_2401_17122
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Study of Applicability of Simple Closed Loop Input Impedance Model for Grid-Tie Inverters
Santamargarita, Daniel
Huerta, Francisco
Sanz, Marina
Lazaro, Antonio
DArco, Salvatore
Sanchez, Santiago
Tedeschi, Elisabetta
Roldan, Javier
Systems and Control
In recent years the need for DC distribution buses has increased considerably. As it can be noticed in the transport for example the distribution systems of the more electric aircrafts, ships, or electric cars. Given the complexities of the systems presented above, the need to use more and more switched power converters has arisen. The main problem of the connection of multiple controlled switched converters acting as source and load is the degradation of stability that occurs on the DC distribution bus due to the converter interactions. To study the stability in the distribution bus there are some wellestablished criteria. These criteria require knowledge of the input impedance of the converters that act as load and the output impedance of the equipment that acts as source. In order to reduce the complexity of obtaining the input impedance a model based on a controlled converter acting as a constant power load (CPL) is commonly used. This article studies the accuracy of this model for a commonly used topology in distribution systems nowadays, Two Level Voltage Source Converter (2L-VSC), studying different scenarios that make the model become inaccurate.
title Study of Applicability of Simple Closed Loop Input Impedance Model for Grid-Tie Inverters
topic Systems and Control
url https://arxiv.org/abs/2401.17122