Measurement of the Photon Detection Efficiency of Hamamatsu VUV4 SiPMs at Cryogenic Temperature

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Álvarez-Garrote, Rodrigo, Calvo, Enrique, Canto, Aritz, Crespo-Anadón, José Ignacio, Cuesta, Clara, Rojo, Andrés de la Torre, Gil-Botella, Inés, Corchado, Sergio Manthey, Martín, Iván, Palomares, Carmen, Pérez-Molina, Laura, de Osa, Antonio Verdugo
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911845136203776
author Álvarez-Garrote, Rodrigo
Calvo, Enrique
Canto, Aritz
Crespo-Anadón, José Ignacio
Cuesta, Clara
Rojo, Andrés de la Torre
Gil-Botella, Inés
Corchado, Sergio Manthey
Martín, Iván
Palomares, Carmen
Pérez-Molina, Laura
de Osa, Antonio Verdugo
author_facet Álvarez-Garrote, Rodrigo
Calvo, Enrique
Canto, Aritz
Crespo-Anadón, José Ignacio
Cuesta, Clara
Rojo, Andrés de la Torre
Gil-Botella, Inés
Corchado, Sergio Manthey
Martín, Iván
Palomares, Carmen
Pérez-Molina, Laura
de Osa, Antonio Verdugo
contents Liquid argon time projection chambers (TPC) are widely used in neutrino oscillation and dark matter experiments. Detection of scintillation light in liquid argon TPC's is challenging because of its short wavelength, in the VUV range, and the cryogenic temperatures (~86 K) at which the sensors must operate. Wavelength shifters (WLS) are typically needed to take advantage of the high Photon Detection Efficiency (PDE) in the visible range of most of photondetectors. The Hamamatsu VUV4 S13370--6075CN SiPMs can directly detect VUV light without the use of WLS, which main benefit is an improved PDE at these short wavelengths, but also the visible light from WLS. The manufacturer (Hamamatsu Photonics K.K.) provides a complete characterization of these devices at room temperature; however, previous studies have indicated a decrease of the PDE at cryogenic temperature for VUV light. In this work, we present the measurement of the PDE of VUV4 SiPMs at cryogenic temperature for different wavelengths in the range [270, 570] nm. A dedicated measurement at 127 nm is also shown.
format Preprint
id arxiv_https___arxiv_org_abs_2402_01584
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Measurement of the Photon Detection Efficiency of Hamamatsu VUV4 SiPMs at Cryogenic Temperature
Álvarez-Garrote, Rodrigo
Calvo, Enrique
Canto, Aritz
Crespo-Anadón, José Ignacio
Cuesta, Clara
Rojo, Andrés de la Torre
Gil-Botella, Inés
Corchado, Sergio Manthey
Martín, Iván
Palomares, Carmen
Pérez-Molina, Laura
de Osa, Antonio Verdugo
Instrumentation and Detectors
High Energy Physics - Experiment
Liquid argon time projection chambers (TPC) are widely used in neutrino oscillation and dark matter experiments. Detection of scintillation light in liquid argon TPC's is challenging because of its short wavelength, in the VUV range, and the cryogenic temperatures (~86 K) at which the sensors must operate. Wavelength shifters (WLS) are typically needed to take advantage of the high Photon Detection Efficiency (PDE) in the visible range of most of photondetectors. The Hamamatsu VUV4 S13370--6075CN SiPMs can directly detect VUV light without the use of WLS, which main benefit is an improved PDE at these short wavelengths, but also the visible light from WLS. The manufacturer (Hamamatsu Photonics K.K.) provides a complete characterization of these devices at room temperature; however, previous studies have indicated a decrease of the PDE at cryogenic temperature for VUV light. In this work, we present the measurement of the PDE of VUV4 SiPMs at cryogenic temperature for different wavelengths in the range [270, 570] nm. A dedicated measurement at 127 nm is also shown.
title Measurement of the Photon Detection Efficiency of Hamamatsu VUV4 SiPMs at Cryogenic Temperature
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2402.01584