DCE-FORMER: A Transformer-based Model With Mutual Information And Frequency-based Loss Functions For Early And Late Response Prediction In Prostate DCE-MRI

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: S, Sadhana, Ramanarayanan, Sriprabha, Sarkar, Arunima, Gayathri, Matcha Naga, Ram, Keerthi, Sivaprakasam, Mohanasankar
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929232931717120
author S, Sadhana
Ramanarayanan, Sriprabha
Sarkar, Arunima
Gayathri, Matcha Naga
Ram, Keerthi
Sivaprakasam, Mohanasankar
author_facet S, Sadhana
Ramanarayanan, Sriprabha
Sarkar, Arunima
Gayathri, Matcha Naga
Ram, Keerthi
Sivaprakasam, Mohanasankar
contents Dynamic Contrast Enhanced Magnetic Resonance Imaging aids in the detection and assessment of tumor aggressiveness by using a Gadolinium-based contrast agent (GBCA). However, GBCA is known to have potential toxic effects. This risk can be avoided if we obtain DCE-MRI images without using GBCA. We propose, DCE-former, a transformer-based neural network to generate early and late response prostate DCE-MRI images from non-contrast multimodal inputs (T2 weighted, Apparent Diffusion Coefficient, and T1 pre-contrast MRI). Additionally, we introduce (i) a mutual information loss function to capture the complementary information about contrast uptake, and (ii) a frequency-based loss function in the pixel and Fourier space to learn local and global hyper-intensity patterns in DCE-MRI. Extensive experiments show that DCE-former outperforms other methods with improvement margins of +1.39 dB and +1.19 db in PSNR, +0.068 and +0.055 in SSIM, and -0.012 and -0.013 in Mean Absolute Error for early and late response DCE-MRI, respectively.
format Preprint
id arxiv_https___arxiv_org_abs_2402_02125
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle DCE-FORMER: A Transformer-based Model With Mutual Information And Frequency-based Loss Functions For Early And Late Response Prediction In Prostate DCE-MRI
S, Sadhana
Ramanarayanan, Sriprabha
Sarkar, Arunima
Gayathri, Matcha Naga
Ram, Keerthi
Sivaprakasam, Mohanasankar
Image and Video Processing
Dynamic Contrast Enhanced Magnetic Resonance Imaging aids in the detection and assessment of tumor aggressiveness by using a Gadolinium-based contrast agent (GBCA). However, GBCA is known to have potential toxic effects. This risk can be avoided if we obtain DCE-MRI images without using GBCA. We propose, DCE-former, a transformer-based neural network to generate early and late response prostate DCE-MRI images from non-contrast multimodal inputs (T2 weighted, Apparent Diffusion Coefficient, and T1 pre-contrast MRI). Additionally, we introduce (i) a mutual information loss function to capture the complementary information about contrast uptake, and (ii) a frequency-based loss function in the pixel and Fourier space to learn local and global hyper-intensity patterns in DCE-MRI. Extensive experiments show that DCE-former outperforms other methods with improvement margins of +1.39 dB and +1.19 db in PSNR, +0.068 and +0.055 in SSIM, and -0.012 and -0.013 in Mean Absolute Error for early and late response DCE-MRI, respectively.
title DCE-FORMER: A Transformer-based Model With Mutual Information And Frequency-based Loss Functions For Early And Late Response Prediction In Prostate DCE-MRI
topic Image and Video Processing
url https://arxiv.org/abs/2402.02125