First (calibration) experiment using proton beam from FRENA at SINP

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Basu, C., Banerjee, K., Ghosh, T. K., Mukherjee, G., Bhattacharya, C., Desai, Shraddha S, Shil, R., Saha, A. K., Meena, J. K., Bar, T., Basak, D., Sahoo, L. K., Saha, S., Marick, C., Das, D., Kujur, M., Roy, S., Basu, S. S., Gond, U., Saha, A., Das, A., Samanta, M., Saha, P., Karan, S. K.
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911771281850368
author Basu, C.
Banerjee, K.
Ghosh, T. K.
Mukherjee, G.
Bhattacharya, C.
Desai, Shraddha S
Shil, R.
Saha, A. K.
Meena, J. K.
Bar, T.
Basak, D.
Sahoo, L. K.
Saha, S.
Marick, C.
Das, D.
Das, D.
Das, D.
Kujur, M.
Roy, S.
Basu, S. S.
Gond, U.
Saha, A.
Das, A.
Samanta, M.
Saha, P.
Karan, S. K.
author_facet Basu, C.
Banerjee, K.
Ghosh, T. K.
Mukherjee, G.
Bhattacharya, C.
Desai, Shraddha S
Shil, R.
Saha, A. K.
Meena, J. K.
Bar, T.
Basak, D.
Sahoo, L. K.
Saha, S.
Marick, C.
Das, D.
Das, D.
Das, D.
Kujur, M.
Roy, S.
Basu, S. S.
Gond, U.
Saha, A.
Das, A.
Samanta, M.
Saha, P.
Karan, S. K.
contents This work presents the first calibration experiment of a 3 MV Tandetron accelerator, FRENA, performed in May 2022. The $^7$Li(p,n) reaction threshold was measured to calibrate the terminal voltage measuring device. A LiF target of thickness 175 $μ$g/cm$^2$ was used in the experiment. The measured threshold was 1872$\pm$2.7 keV, indicating 6$-$10 keV energy shift.
format Preprint
id arxiv_https___arxiv_org_abs_2402_03344
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle First (calibration) experiment using proton beam from FRENA at SINP
Basu, C.
Banerjee, K.
Ghosh, T. K.
Mukherjee, G.
Bhattacharya, C.
Desai, Shraddha S
Shil, R.
Saha, A. K.
Meena, J. K.
Bar, T.
Basak, D.
Sahoo, L. K.
Saha, S.
Marick, C.
Das, D.
Das, D.
Das, D.
Kujur, M.
Roy, S.
Basu, S. S.
Gond, U.
Saha, A.
Das, A.
Samanta, M.
Saha, P.
Karan, S. K.
Instrumentation and Detectors
Nuclear Experiment
Accelerator Physics
This work presents the first calibration experiment of a 3 MV Tandetron accelerator, FRENA, performed in May 2022. The $^7$Li(p,n) reaction threshold was measured to calibrate the terminal voltage measuring device. A LiF target of thickness 175 $μ$g/cm$^2$ was used in the experiment. The measured threshold was 1872$\pm$2.7 keV, indicating 6$-$10 keV energy shift.
title First (calibration) experiment using proton beam from FRENA at SINP
topic Instrumentation and Detectors
Nuclear Experiment
Accelerator Physics
url https://arxiv.org/abs/2402.03344