A quantitative assessment of Geant4 for predicting the yield and distribution of positron-emitting fragments in ion beam therapy

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Chacon, Andrew, Rutherford, Harley, Hamato, Akram, Nitta, Munetaka, Nishikido, Fumihiko, Iwao, Yuma, Tashima, Hideaki, Yoshida, Eiji, Akamatsu, Go, Takyu, Sodai, Kang, Han Gyu, Franklin, Daniel R., Parodi, Katia, Yamaya, Taiga, Rosenfeld, Anatoly, Guatelli, Susanna, Safavi-Naeini, Mitra
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866910409273901056
author Chacon, Andrew
Rutherford, Harley
Hamato, Akram
Nitta, Munetaka
Nishikido, Fumihiko
Iwao, Yuma
Tashima, Hideaki
Yoshida, Eiji
Akamatsu, Go
Takyu, Sodai
Kang, Han Gyu
Franklin, Daniel R.
Parodi, Katia
Yamaya, Taiga
Rosenfeld, Anatoly
Guatelli, Susanna
Safavi-Naeini, Mitra
author_facet Chacon, Andrew
Rutherford, Harley
Hamato, Akram
Nitta, Munetaka
Nishikido, Fumihiko
Iwao, Yuma
Tashima, Hideaki
Yoshida, Eiji
Akamatsu, Go
Takyu, Sodai
Kang, Han Gyu
Franklin, Daniel R.
Parodi, Katia
Yamaya, Taiga
Rosenfeld, Anatoly
Guatelli, Susanna
Safavi-Naeini, Mitra
contents Purpose: To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy. Materials and Methods: Phantoms of polyethylene, gelatin or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion beams. Post-irradiation, 4D PET images were acquired and parent $^{11}$C, $^{10}$C and $^{15}$O radionuclides contributions in each voxel were determined from the extracted time activity curves. Experiments were simulated in Geant4 Monte Carlo versions 10-11.1, with three different fragmentation models: binary ion cascade (BIC), quantum molecular dynamics (QMD) and the Liege intranuclear cascade (INCL++) - 30 combinations. Total/parent isotope positron annihilation yields were compared between simulations and experiments using normalised mean squared error and Pearson cross-correlation coefficient. Depth of maximum/distal 50\% peak position yield were also compared. Results: Performance varied considerably across versions and models, with no one best predicting all positron-emitting fragments. BIC in Geant4 10.2 provided the best overall agreement with experimental results in the largest number of test cases. QMD consistently provided the best estimates of both the depth of peak positron yield (10.4 and 10.6) and the distal 50\%-of-peak point (10.2), while BIC also performed well and INCL generally performed the worst across most Geant4 versions. Conclusions: Best spatial prediction of annihilation yield and positron-emitting fragment production during carbon and oxygen ion therapy was found to be 10.2.p03 with BIC or QMD. These version/model combinations are recommended for future heavy ion therapy research.
format Preprint
id arxiv_https___arxiv_org_abs_2402_03499
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A quantitative assessment of Geant4 for predicting the yield and distribution of positron-emitting fragments in ion beam therapy
Chacon, Andrew
Rutherford, Harley
Hamato, Akram
Nitta, Munetaka
Nishikido, Fumihiko
Iwao, Yuma
Tashima, Hideaki
Yoshida, Eiji
Akamatsu, Go
Takyu, Sodai
Kang, Han Gyu
Franklin, Daniel R.
Parodi, Katia
Yamaya, Taiga
Rosenfeld, Anatoly
Guatelli, Susanna
Safavi-Naeini, Mitra
Computational Physics
Medical Physics
Purpose: To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy. Materials and Methods: Phantoms of polyethylene, gelatin or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion beams. Post-irradiation, 4D PET images were acquired and parent $^{11}$C, $^{10}$C and $^{15}$O radionuclides contributions in each voxel were determined from the extracted time activity curves. Experiments were simulated in Geant4 Monte Carlo versions 10-11.1, with three different fragmentation models: binary ion cascade (BIC), quantum molecular dynamics (QMD) and the Liege intranuclear cascade (INCL++) - 30 combinations. Total/parent isotope positron annihilation yields were compared between simulations and experiments using normalised mean squared error and Pearson cross-correlation coefficient. Depth of maximum/distal 50\% peak position yield were also compared. Results: Performance varied considerably across versions and models, with no one best predicting all positron-emitting fragments. BIC in Geant4 10.2 provided the best overall agreement with experimental results in the largest number of test cases. QMD consistently provided the best estimates of both the depth of peak positron yield (10.4 and 10.6) and the distal 50\%-of-peak point (10.2), while BIC also performed well and INCL generally performed the worst across most Geant4 versions. Conclusions: Best spatial prediction of annihilation yield and positron-emitting fragment production during carbon and oxygen ion therapy was found to be 10.2.p03 with BIC or QMD. These version/model combinations are recommended for future heavy ion therapy research.
title A quantitative assessment of Geant4 for predicting the yield and distribution of positron-emitting fragments in ion beam therapy
topic Computational Physics
Medical Physics
url https://arxiv.org/abs/2402.03499