Longevity Studies of CSC Prototypes Operating with Ar+CO$_{2}$ Gas Mixture and Different Fractions of CF$_{4}$

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Barberis, Emanuela, Begovic, Nebojsa, Haubrich, Nicholas, Ignatenko, Mikhail, Korytov, Andrey, Kukral, Ota, Kuznetsova, Ekaterina, Lanaro, Armando, MacCabe, Andrew, Milenovic, Predrag, Milovanovic, Dubravka, Mitselmakher, Guenakh, Radulovic, Aleksandra, Rajcic, Boris, Rosenzweig, Jake, Wang, Bingran, Wang, Jian, Wisecarver, Andrew, Wood, Darien, Yeager, Emma
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866910320010723328
author Barberis, Emanuela
Begovic, Nebojsa
Haubrich, Nicholas
Ignatenko, Mikhail
Korytov, Andrey
Kukral, Ota
Kuznetsova, Ekaterina
Lanaro, Armando
MacCabe, Andrew
Milenovic, Predrag
Milovanovic, Dubravka
Mitselmakher, Guenakh
Radulovic, Aleksandra
Rajcic, Boris
Rosenzweig, Jake
Wang, Bingran
Wang, Jian
Wisecarver, Andrew
Wood, Darien
Yeager, Emma
author_facet Barberis, Emanuela
Begovic, Nebojsa
Haubrich, Nicholas
Ignatenko, Mikhail
Korytov, Andrey
Kukral, Ota
Kuznetsova, Ekaterina
Lanaro, Armando
MacCabe, Andrew
Milenovic, Predrag
Milovanovic, Dubravka
Mitselmakher, Guenakh
Radulovic, Aleksandra
Rajcic, Boris
Rosenzweig, Jake
Wang, Bingran
Wang, Jian
Wisecarver, Andrew
Wood, Darien
Yeager, Emma
contents Studies of Cathode Strip Chamber longevity, comparing Ar+CO2 gas mixtures with fractions of 5%, 2%, and 0% CF4, were performed using several small cathode strip prototype chambers. In each trial, a localized source of radiation was used to irradiate up to an accumulated charge of about 300 mC/cm. Additionally, longevity of a uniformly irradiated prototype operating with 2% CF4 was studied at the CERN Gamma Irradiation Facility GIF++. Post-hoc analysis of the chamber electrodes using spectroscopy techniques was also done.
format Preprint
id arxiv_https___arxiv_org_abs_2402_04181
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Longevity Studies of CSC Prototypes Operating with Ar+CO$_{2}$ Gas Mixture and Different Fractions of CF$_{4}$
Barberis, Emanuela
Begovic, Nebojsa
Haubrich, Nicholas
Ignatenko, Mikhail
Korytov, Andrey
Kukral, Ota
Kuznetsova, Ekaterina
Lanaro, Armando
MacCabe, Andrew
Milenovic, Predrag
Milovanovic, Dubravka
Mitselmakher, Guenakh
Radulovic, Aleksandra
Rajcic, Boris
Rosenzweig, Jake
Wang, Bingran
Wang, Jian
Wisecarver, Andrew
Wood, Darien
Yeager, Emma
Instrumentation and Detectors
Studies of Cathode Strip Chamber longevity, comparing Ar+CO2 gas mixtures with fractions of 5%, 2%, and 0% CF4, were performed using several small cathode strip prototype chambers. In each trial, a localized source of radiation was used to irradiate up to an accumulated charge of about 300 mC/cm. Additionally, longevity of a uniformly irradiated prototype operating with 2% CF4 was studied at the CERN Gamma Irradiation Facility GIF++. Post-hoc analysis of the chamber electrodes using spectroscopy techniques was also done.
title Longevity Studies of CSC Prototypes Operating with Ar+CO$_{2}$ Gas Mixture and Different Fractions of CF$_{4}$
topic Instrumentation and Detectors
url https://arxiv.org/abs/2402.04181