Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Temples, Dylan J, Wen, Osmond, Ramanathan, Karthik, Aralis, Taylor, Chang, Yen-Yung, Golwala, Sunil, Hsu, Lauren, Bathurst, Corey, Baxter, Daniel, Bowring, Daniel, Chen, Ran, Figueroa-Feliciano, Enectali, Hollister, Matthew, James, Christopher, Kennard, Kyle, Kurinsky, Noah, Lewis, Samantha, Lukens, Patrick, Novati, Valentina, Ren, Runze, Schmidt, Benjamin
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914982491324416
author Temples, Dylan J
Wen, Osmond
Ramanathan, Karthik
Aralis, Taylor
Chang, Yen-Yung
Golwala, Sunil
Hsu, Lauren
Bathurst, Corey
Baxter, Daniel
Bowring, Daniel
Chen, Ran
Figueroa-Feliciano, Enectali
Hollister, Matthew
James, Christopher
Kennard, Kyle
Kurinsky, Noah
Lewis, Samantha
Lukens, Patrick
Novati, Valentina
Ren, Runze
Schmidt, Benjamin
author_facet Temples, Dylan J
Wen, Osmond
Ramanathan, Karthik
Aralis, Taylor
Chang, Yen-Yung
Golwala, Sunil
Hsu, Lauren
Bathurst, Corey
Baxter, Daniel
Bowring, Daniel
Chen, Ran
Figueroa-Feliciano, Enectali
Hollister, Matthew
James, Christopher
Kennard, Kyle
Kurinsky, Noah
Lewis, Samantha
Lukens, Patrick
Novati, Valentina
Ren, Runze
Schmidt, Benjamin
contents Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the NEXUS low-background facility at Fermilab for characterization and evaluation of this detector architecture's efficacy for a dark matter search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470 nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of $2.1\pm0.2$ eV, a factor of two better than the current state-of-the-art, enabled by millisecond-scale quasiparticle lifetimes. However, due to the sub-percent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to $σ_E=318 \pm 28$ eV. We further model the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, as well as the observed noise spectra, both of which impact the baseline resolution of the sensor.
format Preprint
id arxiv_https___arxiv_org_abs_2402_04473
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility
Temples, Dylan J
Wen, Osmond
Ramanathan, Karthik
Aralis, Taylor
Chang, Yen-Yung
Golwala, Sunil
Hsu, Lauren
Bathurst, Corey
Baxter, Daniel
Bowring, Daniel
Chen, Ran
Figueroa-Feliciano, Enectali
Hollister, Matthew
James, Christopher
Kennard, Kyle
Kurinsky, Noah
Lewis, Samantha
Lukens, Patrick
Novati, Valentina
Ren, Runze
Schmidt, Benjamin
Instrumentation and Detectors
High Energy Physics - Experiment
Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the NEXUS low-background facility at Fermilab for characterization and evaluation of this detector architecture's efficacy for a dark matter search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470 nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of $2.1\pm0.2$ eV, a factor of two better than the current state-of-the-art, enabled by millisecond-scale quasiparticle lifetimes. However, due to the sub-percent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to $σ_E=318 \pm 28$ eV. We further model the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, as well as the observed noise spectra, both of which impact the baseline resolution of the sensor.
title Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2402.04473