First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Hoch, Nora, Seidel, Olivia, Chirayath, Varghese A., Enriquez, Alfredo, Gramellini, Elena, Guenette, Roxanne, Jaidee, I-See W., Keefe, Kevin, Kohani, Shahab, Kubota, Shion, Mahdy, Hany, McDonald, Austin, Mei, Yuan, Miao, Peng, Newcomer, F. Mitch, Nygren, David, Parmaksiz, Ilker, Rooks, Michael, Tzoka, Iakovos, Wei, Wenzhao, Asaadi, Jonathan, Battat, James B. R.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866915031855136768
author Hoch, Nora
Seidel, Olivia
Chirayath, Varghese A.
Enriquez, Alfredo
Gramellini, Elena
Guenette, Roxanne
Jaidee, I-See W.
Keefe, Kevin
Kohani, Shahab
Kubota, Shion
Mahdy, Hany
McDonald, Austin
Mei, Yuan
Miao, Peng
Newcomer, F. Mitch
Nygren, David
Parmaksiz, Ilker
Rooks, Michael
Tzoka, Iakovos
Wei, Wenzhao
Asaadi, Jonathan
Battat, James B. R.
author_facet Hoch, Nora
Seidel, Olivia
Chirayath, Varghese A.
Enriquez, Alfredo
Gramellini, Elena
Guenette, Roxanne
Jaidee, I-See W.
Keefe, Kevin
Kohani, Shahab
Kubota, Shion
Mahdy, Hany
McDonald, Austin
Mei, Yuan
Miao, Peng
Newcomer, F. Mitch
Nygren, David
Parmaksiz, Ilker
Rooks, Michael
Tzoka, Iakovos
Wei, Wenzhao
Asaadi, Jonathan
Battat, James B. R.
contents We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200-1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.
format Preprint
id arxiv_https___arxiv_org_abs_2402_05734
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber
Hoch, Nora
Seidel, Olivia
Chirayath, Varghese A.
Enriquez, Alfredo
Gramellini, Elena
Guenette, Roxanne
Jaidee, I-See W.
Keefe, Kevin
Kohani, Shahab
Kubota, Shion
Mahdy, Hany
McDonald, Austin
Mei, Yuan
Miao, Peng
Newcomer, F. Mitch
Nygren, David
Parmaksiz, Ilker
Rooks, Michael
Tzoka, Iakovos
Wei, Wenzhao
Asaadi, Jonathan
Battat, James B. R.
High Energy Physics - Experiment
Instrumentation and Detectors
We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200-1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.
title First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber
topic High Energy Physics - Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2402.05734