Development and validation of an artificial intelligence model to accurately predict spinopelvic parameters

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Harake, Edward S., Linzey, Joseph R., Jiang, Cheng, Joshi, Rushikesh S., Zaki, Mark M., Jones, Jaes C., Khalsa, Siri S., Lee, John H., Wilseck, Zachary, Joseph, Jacob R., Hollon, Todd C., Park, Paul
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866914672080322560
author Harake, Edward S.
Linzey, Joseph R.
Jiang, Cheng
Joshi, Rushikesh S.
Zaki, Mark M.
Jones, Jaes C.
Khalsa, Siri S.
Lee, John H.
Wilseck, Zachary
Joseph, Jacob R.
Hollon, Todd C.
Park, Paul
author_facet Harake, Edward S.
Linzey, Joseph R.
Jiang, Cheng
Joshi, Rushikesh S.
Zaki, Mark M.
Jones, Jaes C.
Khalsa, Siri S.
Lee, John H.
Wilseck, Zachary
Joseph, Jacob R.
Hollon, Todd C.
Park, Paul
contents Objective. Achieving appropriate spinopelvic alignment has been shown to be associated with improved clinical symptoms. However, measurement of spinopelvic radiographic parameters is time-intensive and interobserver reliability is a concern. Automated measurement tools have the promise of rapid and consistent measurements, but existing tools are still limited by some degree of manual user-entry requirements. This study presents a novel artificial intelligence (AI) tool called SpinePose that automatically predicts spinopelvic parameters with high accuracy without the need for manual entry. Methods. SpinePose was trained and validated on 761 sagittal whole-spine X-rays to predict sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), lumbar lordosis (LL), T1-pelvic angle (T1PA), and L1-pelvic angle (L1PA). A separate test set of 40 X-rays was labeled by 4 reviewers, including fellowship-trained spine surgeons and a fellowship-trained radiologist with neuroradiology subspecialty certification. Median errors relative to the most senior reviewer were calculated to determine model accuracy on test images. Intraclass correlation coefficients (ICC) were used to assess inter-rater reliability. Results. SpinePose exhibited the following median (interquartile range) parameter errors: SVA: 2.2(2.3)mm, p=0.93; PT: 1.3(1.2)°, p=0.48; SS: 1.7(2.2)°, p=0.64; PI: 2.2(2.1)°, p=0.24; LL: 2.6(4.0)°, p=0.89; T1PA: 1.1(0.9)°, p=0.42; and L1PA: 1.4(1.6)°, p=0.49. Model predictions also exhibited excellent reliability at all parameters (ICC: 0.91-1.0). Conclusions. SpinePose accurately predicted spinopelvic parameters with excellent reliability comparable to fellowship-trained spine surgeons and neuroradiologists. Utilization of predictive AI tools in spinal imaging can substantially aid in patient selection and surgical planning.
format Preprint
id arxiv_https___arxiv_org_abs_2402_06185
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Development and validation of an artificial intelligence model to accurately predict spinopelvic parameters
Harake, Edward S.
Linzey, Joseph R.
Jiang, Cheng
Joshi, Rushikesh S.
Zaki, Mark M.
Jones, Jaes C.
Khalsa, Siri S.
Lee, John H.
Wilseck, Zachary
Joseph, Jacob R.
Hollon, Todd C.
Park, Paul
Computer Vision and Pattern Recognition
Artificial Intelligence
Machine Learning
Objective. Achieving appropriate spinopelvic alignment has been shown to be associated with improved clinical symptoms. However, measurement of spinopelvic radiographic parameters is time-intensive and interobserver reliability is a concern. Automated measurement tools have the promise of rapid and consistent measurements, but existing tools are still limited by some degree of manual user-entry requirements. This study presents a novel artificial intelligence (AI) tool called SpinePose that automatically predicts spinopelvic parameters with high accuracy without the need for manual entry. Methods. SpinePose was trained and validated on 761 sagittal whole-spine X-rays to predict sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), lumbar lordosis (LL), T1-pelvic angle (T1PA), and L1-pelvic angle (L1PA). A separate test set of 40 X-rays was labeled by 4 reviewers, including fellowship-trained spine surgeons and a fellowship-trained radiologist with neuroradiology subspecialty certification. Median errors relative to the most senior reviewer were calculated to determine model accuracy on test images. Intraclass correlation coefficients (ICC) were used to assess inter-rater reliability. Results. SpinePose exhibited the following median (interquartile range) parameter errors: SVA: 2.2(2.3)mm, p=0.93; PT: 1.3(1.2)°, p=0.48; SS: 1.7(2.2)°, p=0.64; PI: 2.2(2.1)°, p=0.24; LL: 2.6(4.0)°, p=0.89; T1PA: 1.1(0.9)°, p=0.42; and L1PA: 1.4(1.6)°, p=0.49. Model predictions also exhibited excellent reliability at all parameters (ICC: 0.91-1.0). Conclusions. SpinePose accurately predicted spinopelvic parameters with excellent reliability comparable to fellowship-trained spine surgeons and neuroradiologists. Utilization of predictive AI tools in spinal imaging can substantially aid in patient selection and surgical planning.
title Development and validation of an artificial intelligence model to accurately predict spinopelvic parameters
topic Computer Vision and Pattern Recognition
Artificial Intelligence
Machine Learning
url https://arxiv.org/abs/2402.06185