N-1 Reduced Optimal Power Flow Using Augmented Hierarchical Graph Neural Network

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Pham, Thuan, Li, Xingpeng
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866910323758333952
author Pham, Thuan
Li, Xingpeng
author_facet Pham, Thuan
Li, Xingpeng
contents Optimal power flow (OPF) is used to perform generation redispatch in power system real-time operations. N-1 OPF can ensure safe grid operations under diverse contingency scenarios. For large and intricate power networks with numerous variables and constraints, achieving an optimal solution for real-time N-1 OPF necessitates substantial computational resources. To mitigate this challenge, machine learning (ML) is introduced as an additional tool for predicting congested or heavily loaded lines dynamically. In this paper, an advanced ML model known as the augmented hierarchical graph neural network (AHGNN) was proposed to predict critical congested lines and create N-1 reduced OPF (N-1 ROPF). The proposed AHGNN-enabled N-1 ROPF can result in a remarkable reduction in computing time while retaining the solution quality. Several variations of GNN-based ML models are also implemented as benchmark to demonstrate effectiveness of the proposed AHGNN approach. Case studies prove the proposed AHGNN and the associated N-1 ROPF are highly effective in reducing computation time while preserving solution quality, highlighting the promising potential of ML, particularly GNN in enhancing power system operations.
format Preprint
id arxiv_https___arxiv_org_abs_2402_06226
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle N-1 Reduced Optimal Power Flow Using Augmented Hierarchical Graph Neural Network
Pham, Thuan
Li, Xingpeng
Systems and Control
Machine Learning
Optimal power flow (OPF) is used to perform generation redispatch in power system real-time operations. N-1 OPF can ensure safe grid operations under diverse contingency scenarios. For large and intricate power networks with numerous variables and constraints, achieving an optimal solution for real-time N-1 OPF necessitates substantial computational resources. To mitigate this challenge, machine learning (ML) is introduced as an additional tool for predicting congested or heavily loaded lines dynamically. In this paper, an advanced ML model known as the augmented hierarchical graph neural network (AHGNN) was proposed to predict critical congested lines and create N-1 reduced OPF (N-1 ROPF). The proposed AHGNN-enabled N-1 ROPF can result in a remarkable reduction in computing time while retaining the solution quality. Several variations of GNN-based ML models are also implemented as benchmark to demonstrate effectiveness of the proposed AHGNN approach. Case studies prove the proposed AHGNN and the associated N-1 ROPF are highly effective in reducing computation time while preserving solution quality, highlighting the promising potential of ML, particularly GNN in enhancing power system operations.
title N-1 Reduced Optimal Power Flow Using Augmented Hierarchical Graph Neural Network
topic Systems and Control
Machine Learning
url https://arxiv.org/abs/2402.06226