An integrated heart-torso electromechanical model for the simulation of electrophysiogical outputs accounting for myocardial deformation

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Zappon, Elena, Salvador, Matteo, Piersanti, Roberto, Regazzoni, Francesco, Dede', Luca, Quarteroni, Alfio
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866929238790111232
author Zappon, Elena
Salvador, Matteo
Piersanti, Roberto
Regazzoni, Francesco
Dede', Luca
Quarteroni, Alfio
author_facet Zappon, Elena
Salvador, Matteo
Piersanti, Roberto
Regazzoni, Francesco
Dede', Luca
Quarteroni, Alfio
contents When generating in-silico clinical electrophysiological outputs, such as electrocardiograms (ECGs) and body surface potential maps (BSPMs), mathematical models have relied on single physics, i.e. of the cardiac electrophysiology (EP), neglecting the role of the heart motion. Since the heart is the most powerful source of electrical activity in the human body, its motion dynamically shifts the position of the principal electrical sources in the torso, influencing electrical potential distribution and potentially altering the EP outputs. In this work, we propose a computational model for the simulation of ECGs and BSPMs by coupling a cardiac electromechanical model with a model that simulates the propagation of the EP signal in the torso, thanks to a flexible numerical approach, that simulates the torso domain deformation induced by the myocardial displacement. Our model accounts for the major mechano-electrical feedbacks, along with unidirectional displacement and potential couplings from the heart to the surrounding body. For the numerical discretization, we employ a versatile intergrid transfer operator that allows for the use of different Finite Element spaces to be used in the cardiac and torso domains. Our numerical results are obtained on a realistic 3D biventricular-torso geometry, and cover both cases of sinus rhythm and ventricular tachycardia (VT), solving both the electromechanical-torso model in dynamical domains, and the classical electrophysiology-torso model in static domains. By comparing standard 12-lead ECG and BSPMs, we highlight the non-negligible effects of the myocardial contraction on the EP-outputs, especially in pathological conditions, such as the VT.
format Preprint
id arxiv_https___arxiv_org_abs_2402_06308
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle An integrated heart-torso electromechanical model for the simulation of electrophysiogical outputs accounting for myocardial deformation
Zappon, Elena
Salvador, Matteo
Piersanti, Roberto
Regazzoni, Francesco
Dede', Luca
Quarteroni, Alfio
Numerical Analysis
65Z05, 92C10, 92C50
G.1.10; I.6.5; I.6.4; J.3
When generating in-silico clinical electrophysiological outputs, such as electrocardiograms (ECGs) and body surface potential maps (BSPMs), mathematical models have relied on single physics, i.e. of the cardiac electrophysiology (EP), neglecting the role of the heart motion. Since the heart is the most powerful source of electrical activity in the human body, its motion dynamically shifts the position of the principal electrical sources in the torso, influencing electrical potential distribution and potentially altering the EP outputs. In this work, we propose a computational model for the simulation of ECGs and BSPMs by coupling a cardiac electromechanical model with a model that simulates the propagation of the EP signal in the torso, thanks to a flexible numerical approach, that simulates the torso domain deformation induced by the myocardial displacement. Our model accounts for the major mechano-electrical feedbacks, along with unidirectional displacement and potential couplings from the heart to the surrounding body. For the numerical discretization, we employ a versatile intergrid transfer operator that allows for the use of different Finite Element spaces to be used in the cardiac and torso domains. Our numerical results are obtained on a realistic 3D biventricular-torso geometry, and cover both cases of sinus rhythm and ventricular tachycardia (VT), solving both the electromechanical-torso model in dynamical domains, and the classical electrophysiology-torso model in static domains. By comparing standard 12-lead ECG and BSPMs, we highlight the non-negligible effects of the myocardial contraction on the EP-outputs, especially in pathological conditions, such as the VT.
title An integrated heart-torso electromechanical model for the simulation of electrophysiogical outputs accounting for myocardial deformation
topic Numerical Analysis
65Z05, 92C10, 92C50
G.1.10; I.6.5; I.6.4; J.3
url https://arxiv.org/abs/2402.06308