comparison of two models to predict vertebral failure loads on the same experimental dataset

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Allard, V., Heidsieck, C., Bermond, F., Confavreux, C., Travert, C., Gajny, L., 3, Skalli, W., Mitton, D., Follet, H.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913234478432256
author Allard, V.
Heidsieck, C.
Bermond, F.
Confavreux, C.
Travert, C.
Gajny, L.
3
Skalli, W.
Mitton, D.
Follet, H.
author_facet Allard, V.
Heidsieck, C.
Bermond, F.
Confavreux, C.
Travert, C.
Gajny, L.
3
Skalli, W.
Mitton, D.
Follet, H.
contents Clinical use of finite element analysis requires validation and reproducibility studies. The current study compared two models of vertebral bodies including endplates, on the same experimental dataset and evaluated the influence of the operator on the failure load. Models used were strongly correlated (R2=0.91). The intra-operator reproducibility was 6.4% and 3.5 % for each model. Both simulated results were close to experimental results. The differences in performance could be associated to the differences in segmentation process, mesh (hexahedral vs tetrahedral), material representation and failure criteria. Linear analysis did not decrease model accuracy. Comparison with literature for accuracy and precision shows a wide range of values partly related to the different experimental datasets and the different modelling approaches. Models benchmark using the same experimental dataset are needed to go towards clinical applications.
format Preprint
id arxiv_https___arxiv_org_abs_2402_09196
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle comparison of two models to predict vertebral failure loads on the same experimental dataset
Allard, V.
Heidsieck, C.
Bermond, F.
Confavreux, C.
Travert, C.
Gajny, L.
3
Skalli, W.
Mitton, D.
Follet, H.
Numerical Analysis
Clinical use of finite element analysis requires validation and reproducibility studies. The current study compared two models of vertebral bodies including endplates, on the same experimental dataset and evaluated the influence of the operator on the failure load. Models used were strongly correlated (R2=0.91). The intra-operator reproducibility was 6.4% and 3.5 % for each model. Both simulated results were close to experimental results. The differences in performance could be associated to the differences in segmentation process, mesh (hexahedral vs tetrahedral), material representation and failure criteria. Linear analysis did not decrease model accuracy. Comparison with literature for accuracy and precision shows a wide range of values partly related to the different experimental datasets and the different modelling approaches. Models benchmark using the same experimental dataset are needed to go towards clinical applications.
title comparison of two models to predict vertebral failure loads on the same experimental dataset
topic Numerical Analysis
url https://arxiv.org/abs/2402.09196