Demonstration of nuclear gamma-ray polarimetry based on a multi-layer CdTe Compton Camera

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Go, S., Tsuzuki, Y., Yoneda, H., Ichikawa, Y., Ikeda, T., Imai, N., Imamura, K., Niikura, M., Nishimura, D., Mizuno, R., Takeda, S., Ueno, H., Watanabe, S., Saito, T. Y., Shimoura, S., Sugawara, S., Takamine, A., Takahashi, T.
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866913235229212672
author Go, S.
Tsuzuki, Y.
Yoneda, H.
Ichikawa, Y.
Ikeda, T.
Imai, N.
Imamura, K.
Niikura, M.
Nishimura, D.
Mizuno, R.
Takeda, S.
Ueno, H.
Watanabe, S.
Saito, T. Y.
Shimoura, S.
Sugawara, S.
Takamine, A.
Takahashi, T.
author_facet Go, S.
Tsuzuki, Y.
Yoneda, H.
Ichikawa, Y.
Ikeda, T.
Imai, N.
Imamura, K.
Niikura, M.
Nishimura, D.
Mizuno, R.
Takeda, S.
Ueno, H.
Watanabe, S.
Saito, T. Y.
Shimoura, S.
Sugawara, S.
Takamine, A.
Takahashi, T.
contents To detect and track structural changes in atomic nuclei, the systematic study of nuclear levels with firm spin-parity assignments is important. While linear polarization measurements have been applied to determine the electromagnetic character of gamma-ray transitions, the applicable range is strongly limited due to the low efficiency of the detection system. The multi-layer Cadmium-Telluride (CdTe) Compton camera can be a state-of-the-art gamma-ray polarimeter for nuclear spectroscopy with the high position sensitivity and the detection efficiency. We demonstrated the capability to operate this detector as a reliable gamma-ray polarimeter by using polarized 847-keV gamma rays produced by the $^{56}\rm{Fe}({\it p},{\it p'}γ)$ reaction. By combining the experimental data and simulated calculations, the modulation curve for the gamma ray was successfully obtained. A remarkably high polarization sensitivity was achieved, compatible with a reasonable detection efficiency. Based on the obtained results, a possible future gamma-ray polarimetery is discussed.
format Preprint
id arxiv_https___arxiv_org_abs_2402_09652
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Demonstration of nuclear gamma-ray polarimetry based on a multi-layer CdTe Compton Camera
Go, S.
Tsuzuki, Y.
Yoneda, H.
Ichikawa, Y.
Ikeda, T.
Imai, N.
Imamura, K.
Niikura, M.
Nishimura, D.
Mizuno, R.
Takeda, S.
Ueno, H.
Watanabe, S.
Saito, T. Y.
Shimoura, S.
Sugawara, S.
Takamine, A.
Takahashi, T.
Instrumentation and Methods for Astrophysics
Nuclear Experiment
Instrumentation and Detectors
To detect and track structural changes in atomic nuclei, the systematic study of nuclear levels with firm spin-parity assignments is important. While linear polarization measurements have been applied to determine the electromagnetic character of gamma-ray transitions, the applicable range is strongly limited due to the low efficiency of the detection system. The multi-layer Cadmium-Telluride (CdTe) Compton camera can be a state-of-the-art gamma-ray polarimeter for nuclear spectroscopy with the high position sensitivity and the detection efficiency. We demonstrated the capability to operate this detector as a reliable gamma-ray polarimeter by using polarized 847-keV gamma rays produced by the $^{56}\rm{Fe}({\it p},{\it p'}γ)$ reaction. By combining the experimental data and simulated calculations, the modulation curve for the gamma ray was successfully obtained. A remarkably high polarization sensitivity was achieved, compatible with a reasonable detection efficiency. Based on the obtained results, a possible future gamma-ray polarimetery is discussed.
title Demonstration of nuclear gamma-ray polarimetry based on a multi-layer CdTe Compton Camera
topic Instrumentation and Methods for Astrophysics
Nuclear Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2402.09652