Particle detection performance and Geant4 simulation with low-cost CMOS technology

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Del Alamo, M. Bonnett, Helaconde, R., Soncco, C., Bazo, J., Gago, A. M.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913896954068992
author Del Alamo, M. Bonnett
Helaconde, R.
Soncco, C.
Bazo, J.
Gago, A. M.
author_facet Del Alamo, M. Bonnett
Helaconde, R.
Soncco, C.
Bazo, J.
Gago, A. M.
contents We evaluate the performance of an Omnivision OV5647 CMOS image sensor (5 Mp) for detecting radiation from Sr90 and Cs137 sources. Our experimental setup uses a Raspberry Pi 3 mini-computer for data acquisition, with image processing using Python and OpenCV libraries. We specify the necessary settings to convert a standard camera into a particle detector sensitive to electrons and photons, including a two-step background filtering procedure. In addition, we implement the first detailed Geant4 simulation that describes the layered geometry and material composition of a commercial CMOS sensor along with the radioactive sources. To enhance the simulation, we include an algorithm for charge diffusion and conversion of the energy deposited by electrons and photons into ADC counts. Our measurements are presented in terms of cluster size, the maximum ADC signal per cluster, and the number of clusters as a function of distance. We find a good agreement between the experimental data and simulation for all these observables, and we can reproduce the correlation between cluster size and maximum ADC signal per cluster. Thus, this simulation, cross-checked with data, can be used to test the feasibility of further particle detection ideas without the need to implement an experimental setup. However, the sensor has limited primary energy resolution and is thus unable to distinguish between different radioactive sources. Nevertheless, given the accurate measurement of energy deposition, the sensor, once calibrated, is suitable for dosimetric measurements of source activities.
format Preprint
id arxiv_https___arxiv_org_abs_2402_13993
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Particle detection performance and Geant4 simulation with low-cost CMOS technology
Del Alamo, M. Bonnett
Helaconde, R.
Soncco, C.
Bazo, J.
Gago, A. M.
High Energy Physics - Experiment
Instrumentation and Detectors
We evaluate the performance of an Omnivision OV5647 CMOS image sensor (5 Mp) for detecting radiation from Sr90 and Cs137 sources. Our experimental setup uses a Raspberry Pi 3 mini-computer for data acquisition, with image processing using Python and OpenCV libraries. We specify the necessary settings to convert a standard camera into a particle detector sensitive to electrons and photons, including a two-step background filtering procedure. In addition, we implement the first detailed Geant4 simulation that describes the layered geometry and material composition of a commercial CMOS sensor along with the radioactive sources. To enhance the simulation, we include an algorithm for charge diffusion and conversion of the energy deposited by electrons and photons into ADC counts. Our measurements are presented in terms of cluster size, the maximum ADC signal per cluster, and the number of clusters as a function of distance. We find a good agreement between the experimental data and simulation for all these observables, and we can reproduce the correlation between cluster size and maximum ADC signal per cluster. Thus, this simulation, cross-checked with data, can be used to test the feasibility of further particle detection ideas without the need to implement an experimental setup. However, the sensor has limited primary energy resolution and is thus unable to distinguish between different radioactive sources. Nevertheless, given the accurate measurement of energy deposition, the sensor, once calibrated, is suitable for dosimetric measurements of source activities.
title Particle detection performance and Geant4 simulation with low-cost CMOS technology
topic High Energy Physics - Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2402.13993