Measurements of low-energy nuclear recoil quenching factors for Na and I recoils in the NaI(Tl) scintillator

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Lee, S. H., Joo, H. W., Kim, H. J., Kim, K. W., Kim, S. K., Kim, Y. D., Ko, Y. J., Lee, H. S., Lee, J. Y., Park, H. S., Yoon, Y. S.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866913421562216448
author Lee, S. H.
Joo, H. W.
Kim, H. J.
Kim, K. W.
Kim, S. K.
Kim, Y. D.
Ko, Y. J.
Lee, H. S.
Lee, J. Y.
Park, H. S.
Yoon, Y. S.
author_facet Lee, S. H.
Joo, H. W.
Kim, H. J.
Kim, K. W.
Kim, S. K.
Kim, Y. D.
Ko, Y. J.
Lee, H. S.
Lee, J. Y.
Park, H. S.
Yoon, Y. S.
contents Elastic scattering off nuclei in target detectors, involving interactions with dark matter and coherent elastic neutrino nuclear recoil (CE$ν$NS), results in the deposition of low energy within the nuclei, dissipating rapidly through a combination of heat and ionization. The primary energy loss mechanism for nuclear recoil is heat, leading to consistently smaller measurable scintillation signals compared to electron recoils of the same energy. The nuclear recoil quenching factor (QF), representing the ratio of scintillation light yield produced by nuclear recoil to that of electron recoil at the same energy, is a critical parameter for understanding dark matter and neutrino interactions with nuclei. The low energy QF of NaI(Tl) crystals, commonly employed in dark matter searches and CE$ν$NS measurements, is of substantial importance. Previous low energy QF measurements were constrained by contamination from photomultiplier tube (PMT)-induced noise, resulting in an observed light yield of approximately 15 photoelectrons per keVee (kilo-electron-volt electron-equivalent energy) and nuclear recoil energy above 5 keVnr (kilo-electron-volt nuclear recoil energy). Through enhanced crystal encapsulation, an increased light yield of around 26 photoelectrons per keVee is achieved. This improvement enables the measurement of the nuclear recoil QF for sodium nuclei at an energy of 3.8 $\pm$ 0.6 keVnr with a QF of 11.2 $\pm$ 1.7%. Furthermore, a reevaluation of previously reported QF results is conducted, incorporating enhancements in low energy events based on waveform simulation. The outcomes are generally consistent with various recent QF measurements for sodium and iodine.
format Preprint
id arxiv_https___arxiv_org_abs_2402_15122
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Measurements of low-energy nuclear recoil quenching factors for Na and I recoils in the NaI(Tl) scintillator
Lee, S. H.
Joo, H. W.
Kim, H. J.
Kim, K. W.
Kim, S. K.
Kim, Y. D.
Ko, Y. J.
Lee, H. S.
Lee, J. Y.
Park, H. S.
Yoon, Y. S.
High Energy Physics - Experiment
Instrumentation and Detectors
Elastic scattering off nuclei in target detectors, involving interactions with dark matter and coherent elastic neutrino nuclear recoil (CE$ν$NS), results in the deposition of low energy within the nuclei, dissipating rapidly through a combination of heat and ionization. The primary energy loss mechanism for nuclear recoil is heat, leading to consistently smaller measurable scintillation signals compared to electron recoils of the same energy. The nuclear recoil quenching factor (QF), representing the ratio of scintillation light yield produced by nuclear recoil to that of electron recoil at the same energy, is a critical parameter for understanding dark matter and neutrino interactions with nuclei. The low energy QF of NaI(Tl) crystals, commonly employed in dark matter searches and CE$ν$NS measurements, is of substantial importance. Previous low energy QF measurements were constrained by contamination from photomultiplier tube (PMT)-induced noise, resulting in an observed light yield of approximately 15 photoelectrons per keVee (kilo-electron-volt electron-equivalent energy) and nuclear recoil energy above 5 keVnr (kilo-electron-volt nuclear recoil energy). Through enhanced crystal encapsulation, an increased light yield of around 26 photoelectrons per keVee is achieved. This improvement enables the measurement of the nuclear recoil QF for sodium nuclei at an energy of 3.8 $\pm$ 0.6 keVnr with a QF of 11.2 $\pm$ 1.7%. Furthermore, a reevaluation of previously reported QF results is conducted, incorporating enhancements in low energy events based on waveform simulation. The outcomes are generally consistent with various recent QF measurements for sodium and iodine.
title Measurements of low-energy nuclear recoil quenching factors for Na and I recoils in the NaI(Tl) scintillator
topic High Energy Physics - Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2402.15122