Achieving a Near-Ideal Silicon Crystal Neutron Interferometer using Sub-Micron Fabrication Techniques

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Huber, M. G., Taminiau, I., Cory, D. G., Heacock, B., Sarenac, D., Valdillez, R., Pushin, D. A.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909119965822976
author Huber, M. G.
Taminiau, I.
Cory, D. G.
Heacock, B.
Sarenac, D.
Valdillez, R.
Pushin, D. A.
author_facet Huber, M. G.
Taminiau, I.
Cory, D. G.
Heacock, B.
Sarenac, D.
Valdillez, R.
Pushin, D. A.
contents Perfect-crystal neutron interferometry which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched in order to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, repeatable non-etching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several separate times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution.
format Preprint
id arxiv_https___arxiv_org_abs_2402_16127
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Achieving a Near-Ideal Silicon Crystal Neutron Interferometer using Sub-Micron Fabrication Techniques
Huber, M. G.
Taminiau, I.
Cory, D. G.
Heacock, B.
Sarenac, D.
Valdillez, R.
Pushin, D. A.
Instrumentation and Detectors
Nuclear Experiment
Perfect-crystal neutron interferometry which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched in order to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, repeatable non-etching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several separate times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution.
title Achieving a Near-Ideal Silicon Crystal Neutron Interferometer using Sub-Micron Fabrication Techniques
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2402.16127