Aging effects in the COMPASS hybrid GEM-Micromegas pixelized detectors

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Neyret, Damien, Abbon, Philippe, Anfreville, Marc, Andrieux, Vincent, Bedfer, Yann, Durand, Dominique, Herlant, Sébastien, d'Hose, Nicole, Kunne, Fabienne, Platchkov, Stephane, Thibaud, Florian, Usseglio, Michel, Vandenbroucke, Maxence
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866916294907920384
author Neyret, Damien
Abbon, Philippe
Anfreville, Marc
Andrieux, Vincent
Bedfer, Yann
Durand, Dominique
Herlant, Sébastien
d'Hose, Nicole
Kunne, Fabienne
Platchkov, Stephane
Thibaud, Florian
Usseglio, Michel
Vandenbroucke, Maxence
author_facet Neyret, Damien
Abbon, Philippe
Anfreville, Marc
Andrieux, Vincent
Bedfer, Yann
Durand, Dominique
Herlant, Sébastien
d'Hose, Nicole
Kunne, Fabienne
Platchkov, Stephane
Thibaud, Florian
Usseglio, Michel
Vandenbroucke, Maxence
contents Large-size hybrid and pixelized GEM-Micromegas gaseous detectors (40x40 cm$^2$ active area) were developed and installed in 2014 and 2015 for the COMPASS2 physics program which started at the same time. That program involved in particular two full years of Drell-Yan studies using a high-intensity pion beam on a thick polarized target. Although the detectors were placed behind a thick absorber, they were exposed to an important flux of low energy neutrons and photons. The detectors were designed to drastically reduce the discharge rate, a major issue for non-resistive Micromegas in high hadron flux, by a factor of more than 100 compared to the former ones. A hybrid solution was chosen where a pre-amplifying GEM foil is placed 2 mm above the micromesh electrode. A pixelized readout was also added in the center of the detector, where the beam is going through, in order to track particles scattered at very low angles. The combination of the hybrid structure and the pixelized central readout allowed the detector to be operated in an environment with particle flux above 10 MHz/cm$^2$ with very good detection efficiencies and spatial resolution. The performance has remained stable since 2015 in terms of gain and resolution, showing the interest of hybrid structures associating a GEM foil to a Micromegas board to protect gaseous detectors against discharges and aging effects
format Preprint
id arxiv_https___arxiv_org_abs_2402_18681
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Aging effects in the COMPASS hybrid GEM-Micromegas pixelized detectors
Neyret, Damien
Abbon, Philippe
Anfreville, Marc
Andrieux, Vincent
Bedfer, Yann
Durand, Dominique
Herlant, Sébastien
d'Hose, Nicole
Kunne, Fabienne
Platchkov, Stephane
Thibaud, Florian
Usseglio, Michel
Vandenbroucke, Maxence
Instrumentation and Detectors
Large-size hybrid and pixelized GEM-Micromegas gaseous detectors (40x40 cm$^2$ active area) were developed and installed in 2014 and 2015 for the COMPASS2 physics program which started at the same time. That program involved in particular two full years of Drell-Yan studies using a high-intensity pion beam on a thick polarized target. Although the detectors were placed behind a thick absorber, they were exposed to an important flux of low energy neutrons and photons. The detectors were designed to drastically reduce the discharge rate, a major issue for non-resistive Micromegas in high hadron flux, by a factor of more than 100 compared to the former ones. A hybrid solution was chosen where a pre-amplifying GEM foil is placed 2 mm above the micromesh electrode. A pixelized readout was also added in the center of the detector, where the beam is going through, in order to track particles scattered at very low angles. The combination of the hybrid structure and the pixelized central readout allowed the detector to be operated in an environment with particle flux above 10 MHz/cm$^2$ with very good detection efficiencies and spatial resolution. The performance has remained stable since 2015 in terms of gain and resolution, showing the interest of hybrid structures associating a GEM foil to a Micromegas board to protect gaseous detectors against discharges and aging effects
title Aging effects in the COMPASS hybrid GEM-Micromegas pixelized detectors
topic Instrumentation and Detectors
url https://arxiv.org/abs/2402.18681