Implementation of Linear Parameter Varying System to Investigate the Impact of Varying Flow Rate on the Lithium-ion Batteries Thermal Management System Performance

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Rabiee, Pedram, Saidi, Mohammad Hassan
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911787961548800
author Rabiee, Pedram
Saidi, Mohammad Hassan
author_facet Rabiee, Pedram
Saidi, Mohammad Hassan
contents Battery thermal management system is an indispensable part of the electric vehicles working with Lithium-ion batteries. Accordingly, lithium-ion batteries modeling, battery heat generation, and thermal management are the main focus of researchers and car manufacturers. To fulfill the need of manufacturers in the design process, a faster model than time-consuming Computational Fluid Dynamics models (CFD) is required. Reduced Order Models (ROM) address this requirement to maintain the accuracy of CFD models while could be compiled faster. Linear Time Invariant (LTI) reduced order model has been used in the literature; however, due to the limitation of LTI system, considering the constant flow rate for the cooling fluid, a Linear Parameter Varying system with three scheduling parameters was developed in this study. It is shown that LPV system results could fit accurately to CFD results in conditions that LTI system cannot maintain accuracy. Moreover, it is shown that applying varying water flow rates could result in a smoother temperature profile.
format Preprint
id arxiv_https___arxiv_org_abs_2403_01334
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Implementation of Linear Parameter Varying System to Investigate the Impact of Varying Flow Rate on the Lithium-ion Batteries Thermal Management System Performance
Rabiee, Pedram
Saidi, Mohammad Hassan
Systems and Control
Battery thermal management system is an indispensable part of the electric vehicles working with Lithium-ion batteries. Accordingly, lithium-ion batteries modeling, battery heat generation, and thermal management are the main focus of researchers and car manufacturers. To fulfill the need of manufacturers in the design process, a faster model than time-consuming Computational Fluid Dynamics models (CFD) is required. Reduced Order Models (ROM) address this requirement to maintain the accuracy of CFD models while could be compiled faster. Linear Time Invariant (LTI) reduced order model has been used in the literature; however, due to the limitation of LTI system, considering the constant flow rate for the cooling fluid, a Linear Parameter Varying system with three scheduling parameters was developed in this study. It is shown that LPV system results could fit accurately to CFD results in conditions that LTI system cannot maintain accuracy. Moreover, it is shown that applying varying water flow rates could result in a smoother temperature profile.
title Implementation of Linear Parameter Varying System to Investigate the Impact of Varying Flow Rate on the Lithium-ion Batteries Thermal Management System Performance
topic Systems and Control
url https://arxiv.org/abs/2403.01334