A mid-infrared dual-comb spectrometer in step-sweep mode for high-resolution molecular spectroscopy

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Lepère, Muriel, Browet, Olivier, Clément, Jean, Vispoel, Bastien, Allmendinger, Pitt, Hayden, Jakob, Eigenmann, Florian, Hugi, Andreas, Mangold, Markus
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909127911931904
author Lepère, Muriel
Browet, Olivier
Clément, Jean
Vispoel, Bastien
Allmendinger, Pitt
Hayden, Jakob
Eigenmann, Florian
Hugi, Andreas
Mangold, Markus
author_facet Lepère, Muriel
Browet, Olivier
Clément, Jean
Vispoel, Bastien
Allmendinger, Pitt
Hayden, Jakob
Eigenmann, Florian
Hugi, Andreas
Mangold, Markus
contents To meet the challenges of high-resolution molecular spectroscopy, increasingly sophisticated spectroscopic techniques were developed. For a long time FTIR and laser-based spectroscopies were used for these studies. The recent development of dual-comb spectroscopy at high-resolution makes this technique a powerful tool for gas phase studies. We report on the use and characterization of the IRis-F1, a tabletop mid-infrared dual-comb spectrometer, in the newly developed step-sweep mode. The resolution of the wavenumber axis is increased by step-wise tuning (interleaving) and accurate measurement of the laser center wavelength and repetition frequency. Doppler limited measurements of N2O and CH4 reveal a wavenumber accuracy of 1E-4 cm-1 on the covered range of > 50 cm-1. Measured half-widths of absorption lines show no systematic broadening, indicating a negligible instrument response function. Finally, measurements of nitrogen pressure broadening coefficients in the v4 band of methane show that quantum cascade laser dual-comb spectroscopy in step-sweep mode is well adapted for measurements of precision spectroscopic data, in particular line shape parameters.
format Preprint
id arxiv_https___arxiv_org_abs_2403_02720
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A mid-infrared dual-comb spectrometer in step-sweep mode for high-resolution molecular spectroscopy
Lepère, Muriel
Browet, Olivier
Clément, Jean
Vispoel, Bastien
Allmendinger, Pitt
Hayden, Jakob
Eigenmann, Florian
Hugi, Andreas
Mangold, Markus
Optics
Instrumentation and Detectors
To meet the challenges of high-resolution molecular spectroscopy, increasingly sophisticated spectroscopic techniques were developed. For a long time FTIR and laser-based spectroscopies were used for these studies. The recent development of dual-comb spectroscopy at high-resolution makes this technique a powerful tool for gas phase studies. We report on the use and characterization of the IRis-F1, a tabletop mid-infrared dual-comb spectrometer, in the newly developed step-sweep mode. The resolution of the wavenumber axis is increased by step-wise tuning (interleaving) and accurate measurement of the laser center wavelength and repetition frequency. Doppler limited measurements of N2O and CH4 reveal a wavenumber accuracy of 1E-4 cm-1 on the covered range of > 50 cm-1. Measured half-widths of absorption lines show no systematic broadening, indicating a negligible instrument response function. Finally, measurements of nitrogen pressure broadening coefficients in the v4 band of methane show that quantum cascade laser dual-comb spectroscopy in step-sweep mode is well adapted for measurements of precision spectroscopic data, in particular line shape parameters.
title A mid-infrared dual-comb spectrometer in step-sweep mode for high-resolution molecular spectroscopy
topic Optics
Instrumentation and Detectors
url https://arxiv.org/abs/2403.02720