Speckle Noise Reduction in Ultrasound Images using Denoising Auto-encoder with Skip Connection

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bhute, Suraj, Mandal, Subhamoy, Guha, Debashree
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866910354073714688
author Bhute, Suraj
Mandal, Subhamoy
Guha, Debashree
author_facet Bhute, Suraj
Mandal, Subhamoy
Guha, Debashree
contents Ultrasound is a widely used medical tool for non-invasive diagnosis, but its images often contain speckle noise which can lower their resolution and contrast-to-noise ratio. This can make it more difficult to extract, recognize, and analyze features in the images, as well as impair the accuracy of computer-assisted diagnostic techniques and the ability of doctors to interpret the images. Reducing speckle noise, therefore, is a crucial step in the preprocessing of ultrasound images. Researchers have proposed several speckle reduction methods, but no single method takes all relevant factors into account. In this paper, we compare seven such methods: Median, Gaussian, Bilateral, Average, Weiner, Anisotropic and Denoising auto-encoder without and with skip connections in terms of their ability to preserve features and edges while effectively reducing noise. In an experimental study, a convolutional noise-removing auto-encoder with skip connection, a deep learning method, was used to improve ultrasound images of breast cancer. This method involved adding speckle noise at various levels. The results of the deep learning method were compared to those of traditional image enhancement methods, and it was found that the proposed method was more effective. To assess the performance of these algorithms, we use three established evaluation metrics and present both filtered images and statistical data.
format Preprint
id arxiv_https___arxiv_org_abs_2403_02750
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Speckle Noise Reduction in Ultrasound Images using Denoising Auto-encoder with Skip Connection
Bhute, Suraj
Mandal, Subhamoy
Guha, Debashree
Image and Video Processing
Artificial Intelligence
Medical Physics
Ultrasound is a widely used medical tool for non-invasive diagnosis, but its images often contain speckle noise which can lower their resolution and contrast-to-noise ratio. This can make it more difficult to extract, recognize, and analyze features in the images, as well as impair the accuracy of computer-assisted diagnostic techniques and the ability of doctors to interpret the images. Reducing speckle noise, therefore, is a crucial step in the preprocessing of ultrasound images. Researchers have proposed several speckle reduction methods, but no single method takes all relevant factors into account. In this paper, we compare seven such methods: Median, Gaussian, Bilateral, Average, Weiner, Anisotropic and Denoising auto-encoder without and with skip connections in terms of their ability to preserve features and edges while effectively reducing noise. In an experimental study, a convolutional noise-removing auto-encoder with skip connection, a deep learning method, was used to improve ultrasound images of breast cancer. This method involved adding speckle noise at various levels. The results of the deep learning method were compared to those of traditional image enhancement methods, and it was found that the proposed method was more effective. To assess the performance of these algorithms, we use three established evaluation metrics and present both filtered images and statistical data.
title Speckle Noise Reduction in Ultrasound Images using Denoising Auto-encoder with Skip Connection
topic Image and Video Processing
Artificial Intelligence
Medical Physics
url https://arxiv.org/abs/2403.02750