Signal Response Model in PandaX-4T
Fuente:
arXiv
Saved in:
| Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Published: |
2024
|
| Subjects: | |
| Online Access: | |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1866913682160615424 |
|---|---|
| author | Luo, Yunyang Bo, Zihao Zhang, Shibo Abdukerim, Abdusalam Cheng, Chen Chen, Wei Chen, Xun Chen, Yunhua Cheng, Zhaokan Cui, Xiangyi Fan, Yingjie Fang, Deqing Fu, Changbo Fu, Mengting Geng, Lisheng Giboni, Karl Gu, Linhui Guo, Xuyuan Han, Chencheng Han, Ke He, Changda He, Jinrong Huang, Di Huang, Yanlin Huang, Zhou Hou, Ruquan Ji, Xiangdong Ju, Yonglin Li, Chenxiang Li, Jiafu Li, Mingchuan Li, Shu Li, Shuaijie Lin, Qing Liu, Jianglai Lu, Xiaoying Luo, Lingyin Ma, Wenbo Ma, Yugang Mao, Yajun Shaheed, Nasir Meng, Yue Ning, Xuyang Qi, Ningchun Qian, Zhicheng Ren, Xiangxiang Shang, Changsong Shang, Xiaofeng Shen, Guofang Si, Lin Sun, Wenliang Tan, Andi Tao, Yi Wang, Anqing Wang, Meng Wang, Qiuhong Wang, Shaobo Wang, Siguang Wang, Wei Wang, Xiuli Wang, Zhou Wei, Yuehuan Wu, Mengmeng Wu, Weihao Xia, Jingkai Xiao, Mengjiao Xiao, Xiang Xie, Pengwei Yan, Binbin Yan, Xiyu Yang, Jijun Yang, Yong Yu, Chunxu Yuan, Jumin Yuan, Ying Yuan, Zhe Zeng, Xinning Zhang, Dan Zhang, Minzhen Zhang, Peng Zhang, Shu Zhang, Tao Zhang, Yingxin Zhang, Yuanyuan Zhao, Li Zheng, Qibin Zhou, Jifang Zhou, Ning Zhou, Xiaopeng Zhou, Yong Zhou, Yubo |
| author_facet | Luo, Yunyang Bo, Zihao Zhang, Shibo Abdukerim, Abdusalam Cheng, Chen Chen, Wei Chen, Xun Chen, Yunhua Cheng, Zhaokan Cui, Xiangyi Fan, Yingjie Fang, Deqing Fu, Changbo Fu, Mengting Geng, Lisheng Giboni, Karl Gu, Linhui Guo, Xuyuan Han, Chencheng Han, Ke He, Changda He, Jinrong Huang, Di Huang, Yanlin Huang, Zhou Hou, Ruquan Ji, Xiangdong Ju, Yonglin Li, Chenxiang Li, Jiafu Li, Mingchuan Li, Shu Li, Shuaijie Lin, Qing Liu, Jianglai Lu, Xiaoying Luo, Lingyin Ma, Wenbo Ma, Yugang Mao, Yajun Shaheed, Nasir Meng, Yue Ning, Xuyang Qi, Ningchun Qian, Zhicheng Ren, Xiangxiang Shang, Changsong Shang, Xiaofeng Shen, Guofang Si, Lin Sun, Wenliang Tan, Andi Tao, Yi Wang, Anqing Wang, Meng Wang, Qiuhong Wang, Shaobo Wang, Siguang Wang, Wei Wang, Xiuli Wang, Zhou Wei, Yuehuan Wu, Mengmeng Wu, Weihao Xia, Jingkai Xiao, Mengjiao Xiao, Xiang Xie, Pengwei Yan, Binbin Yan, Xiyu Yang, Jijun Yang, Yong Yu, Chunxu Yuan, Jumin Yuan, Ying Yuan, Zhe Zeng, Xinning Zhang, Dan Zhang, Minzhen Zhang, Peng Zhang, Shu Zhang, Tao Zhang, Yingxin Zhang, Yuanyuan Zhao, Li Zheng, Qibin Zhou, Jifang Zhou, Ning Zhou, Xiaopeng Zhou, Yong Zhou, Yubo |
| contents | PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as gamma rays and beta particles. The signal response model plays a crucial role in interpreting the data obtained by PandaX-4T. It describes the conversion from the deposited energy by dark matter interactions to the detectable signals within the detector. The signal response model is utilized in various PandaX-4T results. This work provides a comprehensive description of the procedures involved in constructing and parameter-fitting the signal response model for the energy range of approximately 1 keV to 25 keV for electronic recoils and 6 keV to 90 keV for nuclear recoils. It also covers the signal reconstruction, selection, and correction methods, which are crucial components integrated into the signal response model. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2403_04239 |
| institution | arXiv |
| publishDate | 2024 |
| record_format | arxiv |
| spellingShingle | Signal Response Model in PandaX-4T Luo, Yunyang Bo, Zihao Zhang, Shibo Abdukerim, Abdusalam Cheng, Chen Chen, Wei Chen, Xun Chen, Yunhua Cheng, Zhaokan Cui, Xiangyi Fan, Yingjie Fang, Deqing Fu, Changbo Fu, Mengting Geng, Lisheng Giboni, Karl Gu, Linhui Guo, Xuyuan Han, Chencheng Han, Ke He, Changda He, Jinrong Huang, Di Huang, Yanlin Huang, Zhou Hou, Ruquan Ji, Xiangdong Ju, Yonglin Li, Chenxiang Li, Jiafu Li, Mingchuan Li, Shu Li, Shuaijie Lin, Qing Liu, Jianglai Lu, Xiaoying Luo, Lingyin Ma, Wenbo Ma, Yugang Mao, Yajun Shaheed, Nasir Meng, Yue Ning, Xuyang Qi, Ningchun Qian, Zhicheng Ren, Xiangxiang Shang, Changsong Shang, Xiaofeng Shen, Guofang Si, Lin Sun, Wenliang Tan, Andi Tao, Yi Wang, Anqing Wang, Meng Wang, Qiuhong Wang, Shaobo Wang, Siguang Wang, Wei Wang, Xiuli Wang, Zhou Wei, Yuehuan Wu, Mengmeng Wu, Weihao Xia, Jingkai Xiao, Mengjiao Xiao, Xiang Xie, Pengwei Yan, Binbin Yan, Xiyu Yang, Jijun Yang, Yong Yu, Chunxu Yuan, Jumin Yuan, Ying Yuan, Zhe Zeng, Xinning Zhang, Dan Zhang, Minzhen Zhang, Peng Zhang, Shu Zhang, Tao Zhang, Yingxin Zhang, Yuanyuan Zhao, Li Zheng, Qibin Zhou, Jifang Zhou, Ning Zhou, Xiaopeng Zhou, Yong Zhou, Yubo Instrumentation and Detectors High Energy Physics - Experiment PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as gamma rays and beta particles. The signal response model plays a crucial role in interpreting the data obtained by PandaX-4T. It describes the conversion from the deposited energy by dark matter interactions to the detectable signals within the detector. The signal response model is utilized in various PandaX-4T results. This work provides a comprehensive description of the procedures involved in constructing and parameter-fitting the signal response model for the energy range of approximately 1 keV to 25 keV for electronic recoils and 6 keV to 90 keV for nuclear recoils. It also covers the signal reconstruction, selection, and correction methods, which are crucial components integrated into the signal response model. |
| title | Signal Response Model in PandaX-4T |
| topic | Instrumentation and Detectors High Energy Physics - Experiment |
| url | https://arxiv.org/abs/2403.04239 |