Activation measurements of an iodinated contrast media for online range verification in proton therapy

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Espinosa-Rodriguez, A., Onecha, V. V., Nouvilas, V. M., Onsès, S. Viñals i, Ibañez, P., España, S., Sánchez-Parcerisa, D., Udías, J. M., Fraile, L. M.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929267610222592
author Espinosa-Rodriguez, A.
Onecha, V. V.
Nouvilas, V. M.
Onsès, S. Viñals i
Ibañez, P.
España, S.
Sánchez-Parcerisa, D.
Udías, J. M.
Fraile, L. M.
author_facet Espinosa-Rodriguez, A.
Onecha, V. V.
Nouvilas, V. M.
Onsès, S. Viñals i
Ibañez, P.
España, S.
Sánchez-Parcerisa, D.
Udías, J. M.
Fraile, L. M.
contents The use of contrast agents has previously been proposed as a novel method to increase the activation close to the Bragg peak, aiming to improve the quality of proton range monitoring in vivo. In a recent work, we demonstrated the feasibility of $^{127}$I for online verification, thanks to its high cross-section (200 mbarn at 10 MeV) and low energy production threshold for $^{127m}$Xe. The spectroscopy-based method relies on identifying two specific delayed $γ$ lines (at 124.6 and 172.5 keV), which can be analyzed via single-photon emission computed tomography (SPECT). In this work, we present a proof-of-principle study to investigate proton activation in a commercial iodinated contrast media (ICM) for radiology. Five measurements were conducted at different proton energies (6-10 MeV), equivalent to the last millimeters of clinical proton range. Activation in the ICM was measured with four LaBr$_3$(Ce) scintillators. The contribution from iodine was separated from the activation of the solvent, yielding excellent agreement with previously reported data. These results demonstrate the potential of this technique and pave the way for further testing in clinically relevant scenarios.
format Preprint
id arxiv_https___arxiv_org_abs_2403_04415
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Activation measurements of an iodinated contrast media for online range verification in proton therapy
Espinosa-Rodriguez, A.
Onecha, V. V.
Nouvilas, V. M.
Onsès, S. Viñals i
Ibañez, P.
España, S.
Sánchez-Parcerisa, D.
Udías, J. M.
Fraile, L. M.
Medical Physics
Nuclear Experiment
The use of contrast agents has previously been proposed as a novel method to increase the activation close to the Bragg peak, aiming to improve the quality of proton range monitoring in vivo. In a recent work, we demonstrated the feasibility of $^{127}$I for online verification, thanks to its high cross-section (200 mbarn at 10 MeV) and low energy production threshold for $^{127m}$Xe. The spectroscopy-based method relies on identifying two specific delayed $γ$ lines (at 124.6 and 172.5 keV), which can be analyzed via single-photon emission computed tomography (SPECT). In this work, we present a proof-of-principle study to investigate proton activation in a commercial iodinated contrast media (ICM) for radiology. Five measurements were conducted at different proton energies (6-10 MeV), equivalent to the last millimeters of clinical proton range. Activation in the ICM was measured with four LaBr$_3$(Ce) scintillators. The contribution from iodine was separated from the activation of the solvent, yielding excellent agreement with previously reported data. These results demonstrate the potential of this technique and pave the way for further testing in clinically relevant scenarios.
title Activation measurements of an iodinated contrast media for online range verification in proton therapy
topic Medical Physics
Nuclear Experiment
url https://arxiv.org/abs/2403.04415