Development of novel ionization chambers for reference dosimetry in electron FLASH radiotherapy

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Liu, Kevin, Holmes, Shannon, Khan, Ahtesham Ullah, Hooten, Brian, DeWerd, Larry, Schüler, Emil, Beddar, Sam
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866912052421853184
author Liu, Kevin
Holmes, Shannon
Khan, Ahtesham Ullah
Hooten, Brian
DeWerd, Larry
Schüler, Emil
Beddar, Sam
author_facet Liu, Kevin
Holmes, Shannon
Khan, Ahtesham Ullah
Hooten, Brian
DeWerd, Larry
Schüler, Emil
Beddar, Sam
contents The aim of this study was to optimize the design and performance of parallel plate ion chambers for use in ultra-high dose rate (UHDR) dosimetry applications, and evaluate their potential as reference class chambers for calibration purposes. Three chambers were designed and produced: the A11-VAR (0.2-1.0 mm electrode gap, 20 mm diameter collector), the A11-TPP (0.3 mm electrode gap, 20 mm diameter collector), and the A30 (0.3 mm electrode gap, 5.4 mm diameter collector).The chambers underwent full characterization using an UHDR 9 MeV electron beam with individually varied beam parameters of pulse repetition frequency (PRF, 10-120Hz), pulse width (PW, 0.5-4us), and pulse amplitude (0.01-9 Gy/pulse). The response of the ion chambers was evaluated as a function of the dose per pulse (DPP), PRF, PW, dose rate, electric field strength, and electrode gap. The chamber response was found to be dependent on DPP and PW, whose dependencies were mitigated with larger electric field strengths and smaller electrode spacing. At a constant electric field strength, we measured a larger charge collection efficiency (CCE) as a function of DPP for ion chambers with a smaller electrode gap in the A11-VAR. For ion chambers with identical electrode gap (A11-TPP and A30), higher electric field strengths were found to yield better CCE at higher DPP. A PW dependence was observed at low electric field strengths (500 V/mm) for DPP values ranging from 1-5 Gy at PWs ranging from 0.5-4 μs, but at electric field strengths of 1000 V/mm and higher, these effects become negligible. This study confirmed that the charge collection efficiency of ion chambers depends strongly on the electrode spacing and the electric field strength, and also on the DPP and the PW of the UHDR beam. The new finding of this study is that the PW dependence becomes negligible with reduced electrode spacing and increased electric field.
format Preprint
id arxiv_https___arxiv_org_abs_2403_05661
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Development of novel ionization chambers for reference dosimetry in electron FLASH radiotherapy
Liu, Kevin
Holmes, Shannon
Khan, Ahtesham Ullah
Hooten, Brian
DeWerd, Larry
Schüler, Emil
Beddar, Sam
Medical Physics
Instrumentation and Detectors
The aim of this study was to optimize the design and performance of parallel plate ion chambers for use in ultra-high dose rate (UHDR) dosimetry applications, and evaluate their potential as reference class chambers for calibration purposes. Three chambers were designed and produced: the A11-VAR (0.2-1.0 mm electrode gap, 20 mm diameter collector), the A11-TPP (0.3 mm electrode gap, 20 mm diameter collector), and the A30 (0.3 mm electrode gap, 5.4 mm diameter collector).The chambers underwent full characterization using an UHDR 9 MeV electron beam with individually varied beam parameters of pulse repetition frequency (PRF, 10-120Hz), pulse width (PW, 0.5-4us), and pulse amplitude (0.01-9 Gy/pulse). The response of the ion chambers was evaluated as a function of the dose per pulse (DPP), PRF, PW, dose rate, electric field strength, and electrode gap. The chamber response was found to be dependent on DPP and PW, whose dependencies were mitigated with larger electric field strengths and smaller electrode spacing. At a constant electric field strength, we measured a larger charge collection efficiency (CCE) as a function of DPP for ion chambers with a smaller electrode gap in the A11-VAR. For ion chambers with identical electrode gap (A11-TPP and A30), higher electric field strengths were found to yield better CCE at higher DPP. A PW dependence was observed at low electric field strengths (500 V/mm) for DPP values ranging from 1-5 Gy at PWs ranging from 0.5-4 μs, but at electric field strengths of 1000 V/mm and higher, these effects become negligible. This study confirmed that the charge collection efficiency of ion chambers depends strongly on the electrode spacing and the electric field strength, and also on the DPP and the PW of the UHDR beam. The new finding of this study is that the PW dependence becomes negligible with reduced electrode spacing and increased electric field.
title Development of novel ionization chambers for reference dosimetry in electron FLASH radiotherapy