Pre-examinations Improve Automated Metastases Detection on Cranial MRI

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Deike-Hofmann, Katerina, Dancs, Dorottya, Paech, Daniel, Schlemmer, Heinz-Peter, Maier-Hein, Klaus, Bäumer, Philipp, Radbruch, Alexander, Götz, Michael
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914712965349376
author Deike-Hofmann, Katerina
Dancs, Dorottya
Paech, Daniel
Schlemmer, Heinz-Peter
Maier-Hein, Klaus
Bäumer, Philipp
Radbruch, Alexander
Götz, Michael
author_facet Deike-Hofmann, Katerina
Dancs, Dorottya
Paech, Daniel
Schlemmer, Heinz-Peter
Maier-Hein, Klaus
Bäumer, Philipp
Radbruch, Alexander
Götz, Michael
contents Materials and methods: First, a dual-time approach was assessed, for which the CNN was provided sequences of the MRI that initially depicted new MM (diagnosis MRI) as well as of a prediagnosis MRI: inclusion of only contrast-enhanced T1-weighted images (CNNdual_ce) was compared with inclusion of also the native T1-weighted images, T2-weighted images, and FLAIR sequences of both time points (CNNdual_all).Second, results were compared with the corresponding single time approaches, in which the CNN was provided exclusively the respective sequences of the diagnosis MRI.Casewise diagnostic performance parameters were calculated from 5-fold cross-validation. Results: In total, 94 cases with 494 MMs were included. Overall, the highest diagnostic performance was achieved by inclusion of only the contrast-enhanced T1-weighted images of the diagnosis and of a prediagnosis MRI (CNNdual_ce, sensitivity = 73%, PPV = 25%, F1-score = 36%). Using exclusively contrast-enhanced T1-weighted images as input resulted in significantly less false-positives (FPs) compared with inclusion of further sequences beyond contrast-enhanced T1-weighted images (FPs = 5/7 for CNNdual_ce/CNNdual_all, P < 1e-5). Comparison of contrast-enhanced dual and mono time approaches revealed that exclusion of prediagnosis MRI significantly increased FPs (FPs = 5/10 for CNNdual_ce/CNNce, P < 1e-9).Approaches with only native sequences were clearly inferior to CNNs that were provided contrast-enhanced sequences. Conclusions: Automated MM detection on contrast-enhanced T1-weighted images performed with high sensitivity. Frequent FPs due to artifacts and vessels were significantly reduced by additional inclusion of prediagnosis MRI, but not by inclusion of further sequences beyond contrast-enhanced T1-weighted images. Future studies might investigate different change detection architectures for computer-aided detection.
format Preprint
id arxiv_https___arxiv_org_abs_2403_08280
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Pre-examinations Improve Automated Metastases Detection on Cranial MRI
Deike-Hofmann, Katerina
Dancs, Dorottya
Paech, Daniel
Schlemmer, Heinz-Peter
Maier-Hein, Klaus
Bäumer, Philipp
Radbruch, Alexander
Götz, Michael
Image and Video Processing
Computer Vision and Pattern Recognition
Medical Physics
Quantitative Methods
Materials and methods: First, a dual-time approach was assessed, for which the CNN was provided sequences of the MRI that initially depicted new MM (diagnosis MRI) as well as of a prediagnosis MRI: inclusion of only contrast-enhanced T1-weighted images (CNNdual_ce) was compared with inclusion of also the native T1-weighted images, T2-weighted images, and FLAIR sequences of both time points (CNNdual_all).Second, results were compared with the corresponding single time approaches, in which the CNN was provided exclusively the respective sequences of the diagnosis MRI.Casewise diagnostic performance parameters were calculated from 5-fold cross-validation. Results: In total, 94 cases with 494 MMs were included. Overall, the highest diagnostic performance was achieved by inclusion of only the contrast-enhanced T1-weighted images of the diagnosis and of a prediagnosis MRI (CNNdual_ce, sensitivity = 73%, PPV = 25%, F1-score = 36%). Using exclusively contrast-enhanced T1-weighted images as input resulted in significantly less false-positives (FPs) compared with inclusion of further sequences beyond contrast-enhanced T1-weighted images (FPs = 5/7 for CNNdual_ce/CNNdual_all, P < 1e-5). Comparison of contrast-enhanced dual and mono time approaches revealed that exclusion of prediagnosis MRI significantly increased FPs (FPs = 5/10 for CNNdual_ce/CNNce, P < 1e-9).Approaches with only native sequences were clearly inferior to CNNs that were provided contrast-enhanced sequences. Conclusions: Automated MM detection on contrast-enhanced T1-weighted images performed with high sensitivity. Frequent FPs due to artifacts and vessels were significantly reduced by additional inclusion of prediagnosis MRI, but not by inclusion of further sequences beyond contrast-enhanced T1-weighted images. Future studies might investigate different change detection architectures for computer-aided detection.
title Pre-examinations Improve Automated Metastases Detection on Cranial MRI
topic Image and Video Processing
Computer Vision and Pattern Recognition
Medical Physics
Quantitative Methods
url https://arxiv.org/abs/2403.08280