Saved in:
Bibliographic Details
Main Authors: Zhang, Yuting, Liu, Boyang, Bunting, Karina V., Brind, David, Thorley, Alexander, Karwath, Andreas, Lu, Wenqi, Zhou, Diwei, Wang, Xiaoxia, Mobley, Alastair R., Tica, Otilia, Gkoutos, Georgios, Kotecha, Dipak, Duan, Jinming
Format: Preprint
Published: 2024
Subjects:
Online Access:https://arxiv.org/abs/2403.12152
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910371576545280
author Zhang, Yuting
Liu, Boyang
Bunting, Karina V.
Brind, David
Thorley, Alexander
Karwath, Andreas
Lu, Wenqi
Zhou, Diwei
Wang, Xiaoxia
Mobley, Alastair R.
Tica, Otilia
Gkoutos, Georgios
Kotecha, Dipak
Duan, Jinming
author_facet Zhang, Yuting
Liu, Boyang
Bunting, Karina V.
Brind, David
Thorley, Alexander
Karwath, Andreas
Lu, Wenqi
Zhou, Diwei
Wang, Xiaoxia
Mobley, Alastair R.
Tica, Otilia
Gkoutos, Georgios
Kotecha, Dipak
Duan, Jinming
contents The echocardiographic measurement of left ventricular ejection fraction (LVEF) is fundamental to the diagnosis and classification of patients with heart failure (HF). In order to quantify LVEF automatically and accurately, this paper proposes a new pipeline method based on deep neural networks and ensemble learning. Within the pipeline, an Atrous Convolutional Neural Network (ACNN) was first trained to segment the left ventricle (LV), before employing the area-length formulation based on the ellipsoid single-plane model to calculate LVEF values. This formulation required inputs of LV area, derived from segmentation using an improved Jeffrey's method, as well as LV length, derived from a novel ensemble learning model. To further improve the pipeline's accuracy, an automated peak detection algorithm was used to identify end-diastolic and end-systolic frames, avoiding issues with human error. Subsequently, single-beat LVEF values were averaged across all cardiac cycles to obtain the final LVEF. This method was developed and internally validated in an open-source dataset containing 10,030 echocardiograms. The Pearson's correlation coefficient was 0.83 for LVEF prediction compared to expert human analysis (p<0.001), with a subsequent area under the receiver operator curve (AUROC) of 0.98 (95% confidence interval 0.97 to 0.99) for categorisation of HF with reduced ejection (HFrEF; LVEF<40%). In an external dataset with 200 echocardiograms, this method achieved an AUC of 0.90 (95% confidence interval 0.88 to 0.91) for HFrEF assessment. This study demonstrates that an automated neural network-based calculation of LVEF is comparable to expert clinicians performing time-consuming, frame-by-frame manual evaluation of cardiac systolic function.
format Preprint
id arxiv_https___arxiv_org_abs_2403_12152
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Development of Automated Neural Network Prediction for Echocardiographic Left ventricular Ejection Fraction
Zhang, Yuting
Liu, Boyang
Bunting, Karina V.
Brind, David
Thorley, Alexander
Karwath, Andreas
Lu, Wenqi
Zhou, Diwei
Wang, Xiaoxia
Mobley, Alastair R.
Tica, Otilia
Gkoutos, Georgios
Kotecha, Dipak
Duan, Jinming
Computer Vision and Pattern Recognition
The echocardiographic measurement of left ventricular ejection fraction (LVEF) is fundamental to the diagnosis and classification of patients with heart failure (HF). In order to quantify LVEF automatically and accurately, this paper proposes a new pipeline method based on deep neural networks and ensemble learning. Within the pipeline, an Atrous Convolutional Neural Network (ACNN) was first trained to segment the left ventricle (LV), before employing the area-length formulation based on the ellipsoid single-plane model to calculate LVEF values. This formulation required inputs of LV area, derived from segmentation using an improved Jeffrey's method, as well as LV length, derived from a novel ensemble learning model. To further improve the pipeline's accuracy, an automated peak detection algorithm was used to identify end-diastolic and end-systolic frames, avoiding issues with human error. Subsequently, single-beat LVEF values were averaged across all cardiac cycles to obtain the final LVEF. This method was developed and internally validated in an open-source dataset containing 10,030 echocardiograms. The Pearson's correlation coefficient was 0.83 for LVEF prediction compared to expert human analysis (p<0.001), with a subsequent area under the receiver operator curve (AUROC) of 0.98 (95% confidence interval 0.97 to 0.99) for categorisation of HF with reduced ejection (HFrEF; LVEF<40%). In an external dataset with 200 echocardiograms, this method achieved an AUC of 0.90 (95% confidence interval 0.88 to 0.91) for HFrEF assessment. This study demonstrates that an automated neural network-based calculation of LVEF is comparable to expert clinicians performing time-consuming, frame-by-frame manual evaluation of cardiac systolic function.
title Development of Automated Neural Network Prediction for Echocardiographic Left ventricular Ejection Fraction
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2403.12152