Optical Atomic Clock Interrogation Via an Integrated Spiral Cavity Laser

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Loh, William, Reens, David, Kharas, Dave, Sumant, Alkesh, Belanger, Connor, Maxson, Ryan T., Medeiros, Alexander, Setzer, William, Gray, Dodd, DeBry, Kyle, Bruzewicz, Colin D., Plant, Jason, Liddell, John, West, Gavin N., Doshi, Sagar, Roychowdhury, Matthew, Kim, May, Braje, Danielle, Juodawlkis, Paul W., Chiaverini, John, McConnell, Robert
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909142352920576
author Loh, William
Reens, David
Kharas, Dave
Sumant, Alkesh
Belanger, Connor
Maxson, Ryan T.
Medeiros, Alexander
Setzer, William
Gray, Dodd
DeBry, Kyle
Bruzewicz, Colin D.
Plant, Jason
Liddell, John
West, Gavin N.
Doshi, Sagar
Roychowdhury, Matthew
Kim, May
Braje, Danielle
Juodawlkis, Paul W.
Chiaverini, John
McConnell, Robert
author_facet Loh, William
Reens, David
Kharas, Dave
Sumant, Alkesh
Belanger, Connor
Maxson, Ryan T.
Medeiros, Alexander
Setzer, William
Gray, Dodd
DeBry, Kyle
Bruzewicz, Colin D.
Plant, Jason
Liddell, John
West, Gavin N.
Doshi, Sagar
Roychowdhury, Matthew
Kim, May
Braje, Danielle
Juodawlkis, Paul W.
Chiaverini, John
McConnell, Robert
contents Optical atomic clocks have demonstrated revolutionary advances in precision timekeeping, but their applicability to the real world is critically dependent on whether such clocks can operate outside a laboratory setting. The challenge to clock portability stems from the many obstacles not only in miniaturizing the underlying components of the clock $-$ namely the ultrastable laser, the frequency comb, and the atomic reference itself $-$ but also in making the clock resilient to environmental fluctuations. Photonic integration offers one compelling solution to simultaneously address the problems of miniaturization and ruggedization, but brings with it a new set of challenges in recreating the functionality of an optical clock using chip-scale building blocks. The clock laser used for atom interrogation is one particular point of uncertainty, as the performance of the meticulously-engineered bulk-cavity stabilized lasers would be exceptionally difficult to transfer to chip. Here we demonstrate that a chip-integrated ultrahigh quality factor (Q) spiral cavity, when interfaced with a 1348 nm seed laser, reaches a fractional frequency instability of $7.5 \times 10^{-14}$, meeting the stability requirements for interrogating the narrow-linewidth transition of $^{88}$Sr$^+$ upon frequency doubling to 674 nm. In addition to achieving the record for laser stability on chip, we use this laser to showcase the operation of a Sr-ion clock with short-term instability averaging down as $3.9 \times 10^{-14} / \sqrtτ$, where $τ$ is the averaging time. Our demonstration of an optical atomic clock interrogated by an integrated spiral cavity laser opens the door for future advanced clock systems to be entirely constructed using lightweight, portable, and mass-manufacturable integrated optics and electronics.
format Preprint
id arxiv_https___arxiv_org_abs_2403_12794
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Optical Atomic Clock Interrogation Via an Integrated Spiral Cavity Laser
Loh, William
Reens, David
Kharas, Dave
Sumant, Alkesh
Belanger, Connor
Maxson, Ryan T.
Medeiros, Alexander
Setzer, William
Gray, Dodd
DeBry, Kyle
Bruzewicz, Colin D.
Plant, Jason
Liddell, John
West, Gavin N.
Doshi, Sagar
Roychowdhury, Matthew
Kim, May
Braje, Danielle
Juodawlkis, Paul W.
Chiaverini, John
McConnell, Robert
Atomic Physics
Optics
Optical atomic clocks have demonstrated revolutionary advances in precision timekeeping, but their applicability to the real world is critically dependent on whether such clocks can operate outside a laboratory setting. The challenge to clock portability stems from the many obstacles not only in miniaturizing the underlying components of the clock $-$ namely the ultrastable laser, the frequency comb, and the atomic reference itself $-$ but also in making the clock resilient to environmental fluctuations. Photonic integration offers one compelling solution to simultaneously address the problems of miniaturization and ruggedization, but brings with it a new set of challenges in recreating the functionality of an optical clock using chip-scale building blocks. The clock laser used for atom interrogation is one particular point of uncertainty, as the performance of the meticulously-engineered bulk-cavity stabilized lasers would be exceptionally difficult to transfer to chip. Here we demonstrate that a chip-integrated ultrahigh quality factor (Q) spiral cavity, when interfaced with a 1348 nm seed laser, reaches a fractional frequency instability of $7.5 \times 10^{-14}$, meeting the stability requirements for interrogating the narrow-linewidth transition of $^{88}$Sr$^+$ upon frequency doubling to 674 nm. In addition to achieving the record for laser stability on chip, we use this laser to showcase the operation of a Sr-ion clock with short-term instability averaging down as $3.9 \times 10^{-14} / \sqrtτ$, where $τ$ is the averaging time. Our demonstration of an optical atomic clock interrogated by an integrated spiral cavity laser opens the door for future advanced clock systems to be entirely constructed using lightweight, portable, and mass-manufacturable integrated optics and electronics.
title Optical Atomic Clock Interrogation Via an Integrated Spiral Cavity Laser
topic Atomic Physics
Optics
url https://arxiv.org/abs/2403.12794