Enregistré dans:
Détails bibliographiques
Auteurs principaux: Atibi, Arash, Alqahtani, Abdulaziz, Younis, Mohammed, Preza, Chrysanthe
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:https://arxiv.org/abs/2403.14035
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866911807036194816
author Atibi, Arash
Alqahtani, Abdulaziz
Younis, Mohammed
Preza, Chrysanthe
author_facet Atibi, Arash
Alqahtani, Abdulaziz
Younis, Mohammed
Preza, Chrysanthe
contents We present a study that evaluates the impact of regularization on the achieved resolution in restorations from a novel three-dimensional (3D) Structured Illumination Microscopy (3D-SIM) system with desirable tunability properties. This contribution is the first performance evaluation of the Tunable SIM (TSIM) system through the restoration process. The study quantifies the achieved resolution in restorations, from simulated TSIM data of a 3D star-like object, at various expected resolution limits controlled by system parameters, and at different noise levels mitigated by the Generalized Wiener filter, a computationally efficient method, successfully applied to other conventional 3D-SIM systems. We show that theoretical TSIM resolution limits are attained in the absence of noise, while with increasing noise levels, the necessary increase in regularization and residual restoration artifacts contributed to a $\sim$ 5%-10% and a 20% reduction in the axial achieved resolution, in 20-dB and 15-dB data, respectively, which is within the pixel size (20 nm) limitation.
format Preprint
id arxiv_https___arxiv_org_abs_2403_14035
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Impact of regularization on achieved resolution in 3D tunable structured illumination microscopy (TSIM)
Atibi, Arash
Alqahtani, Abdulaziz
Younis, Mohammed
Preza, Chrysanthe
Image and Video Processing
We present a study that evaluates the impact of regularization on the achieved resolution in restorations from a novel three-dimensional (3D) Structured Illumination Microscopy (3D-SIM) system with desirable tunability properties. This contribution is the first performance evaluation of the Tunable SIM (TSIM) system through the restoration process. The study quantifies the achieved resolution in restorations, from simulated TSIM data of a 3D star-like object, at various expected resolution limits controlled by system parameters, and at different noise levels mitigated by the Generalized Wiener filter, a computationally efficient method, successfully applied to other conventional 3D-SIM systems. We show that theoretical TSIM resolution limits are attained in the absence of noise, while with increasing noise levels, the necessary increase in regularization and residual restoration artifacts contributed to a $\sim$ 5%-10% and a 20% reduction in the axial achieved resolution, in 20-dB and 15-dB data, respectively, which is within the pixel size (20 nm) limitation.
title Impact of regularization on achieved resolution in 3D tunable structured illumination microscopy (TSIM)
topic Image and Video Processing
url https://arxiv.org/abs/2403.14035