Application of the VMM ASIC for SiPM-based calorimetry

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Bearden, I., Buchakchiev, V., Buhl, A., Dufke, L., Isidori, T., Jia, S., Kozhuharov, V., Loizides, C., Muller, H., Pfeiffer, D., Rauch, M., Rusu, A., Simeonov, R.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866916292740513792
author Bearden, I.
Buchakchiev, V.
Buhl, A.
Dufke, L.
Isidori, T.
Jia, S.
Kozhuharov, V.
Loizides, C.
Muller, H.
Pfeiffer, D.
Rauch, M.
Rusu, A.
Simeonov, R.
author_facet Bearden, I.
Buchakchiev, V.
Buhl, A.
Dufke, L.
Isidori, T.
Jia, S.
Kozhuharov, V.
Loizides, C.
Muller, H.
Pfeiffer, D.
Rauch, M.
Rusu, A.
Simeonov, R.
contents Highly integrated multichannel readout electronics is crucial in contemporary particle physics experiments. A novel silicon photomultiplier readout system based on the VMM3a ASIC was developed, for the first time exploiting this chip for calorimetric purposes. To extend the dynamic range the signal from each SiPM channel was processed by two electronics channels with different gain. A fully operational prototype system with 256 SiPM readout channels allowed the collection of data from a prototype of the ALICE Forward Hadron Calorimeter (FoCal-H). The design and the test beam results using high energy hadron beams are presented and discussed, confirming the applicability of VMM3a-based solutions for energy measurements in a high rate environment.
format Preprint
id arxiv_https___arxiv_org_abs_2403_14577
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Application of the VMM ASIC for SiPM-based calorimetry
Bearden, I.
Buchakchiev, V.
Buhl, A.
Dufke, L.
Isidori, T.
Jia, S.
Kozhuharov, V.
Loizides, C.
Muller, H.
Pfeiffer, D.
Rauch, M.
Rusu, A.
Simeonov, R.
Instrumentation and Detectors
Highly integrated multichannel readout electronics is crucial in contemporary particle physics experiments. A novel silicon photomultiplier readout system based on the VMM3a ASIC was developed, for the first time exploiting this chip for calorimetric purposes. To extend the dynamic range the signal from each SiPM channel was processed by two electronics channels with different gain. A fully operational prototype system with 256 SiPM readout channels allowed the collection of data from a prototype of the ALICE Forward Hadron Calorimeter (FoCal-H). The design and the test beam results using high energy hadron beams are presented and discussed, confirming the applicability of VMM3a-based solutions for energy measurements in a high rate environment.
title Application of the VMM ASIC for SiPM-based calorimetry
topic Instrumentation and Detectors
url https://arxiv.org/abs/2403.14577