Radiation Effects on Scientific CMOS Detectors for X-ray Astronomy: II. Total Ionizing Dose Irradiation

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Chen, Mengxi, Ling, Zhixing, Liu, Mingjun, Wu, Qinyu, Zhang, Chen, Liu, Jiaqiang, Zhang, Zhenlong, Yuan, Weimin, Zhang, Shuang-Nan
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914726150144000
author Chen, Mengxi
Ling, Zhixing
Liu, Mingjun
Wu, Qinyu
Zhang, Chen
Liu, Jiaqiang
Zhang, Zhenlong
Yuan, Weimin
Zhang, Shuang-Nan
author_facet Chen, Mengxi
Ling, Zhixing
Liu, Mingjun
Wu, Qinyu
Zhang, Chen
Liu, Jiaqiang
Zhang, Zhenlong
Yuan, Weimin
Zhang, Shuang-Nan
contents Complementary metal-oxide-semiconductor (CMOS) detectors are a competitive choice for current and upcoming astronomical missions. To understand the performance variations of CMOS detectors in space environment, we investigate the total ionizing dose effects on custom-made large-format X-ray CMOS detectors. Three CMOS detector samples were irradiated with a Co-60 source with a total dose of 70 krad and 105 krad. We test and compare the performance of these detectors before and after irradiation. After irradiation, the dark current increases by roughly 20 to 100 times, and the readout noise increases from 3 e- to 6 e-. The bias level at 50 ms integration time decreases by 13 to 18 Digital Number (DN) at -30 degree. The energy resolution increases from about 150 eV to about 170 eV at 4.5 keV at -30 degree. The conversion gain of the detectors varies for less than 2% after the irradiation. Furthermore, there are about 50 pixels whose bias at 50 ms has changed by more than 20 DN after the exposure to the radiation and about 30 to 140 pixels whose readout noise has increased by over 20 e- at -30 degree at 50 ms integration time. These results demonstrate that the performances of large-format CMOS detectors do not suffer significant degeneration in space environment.
format Preprint
id arxiv_https___arxiv_org_abs_2403_15764
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Radiation Effects on Scientific CMOS Detectors for X-ray Astronomy: II. Total Ionizing Dose Irradiation
Chen, Mengxi
Ling, Zhixing
Liu, Mingjun
Wu, Qinyu
Zhang, Chen
Liu, Jiaqiang
Zhang, Zhenlong
Yuan, Weimin
Zhang, Shuang-Nan
Instrumentation and Methods for Astrophysics
High Energy Physics - Experiment
Instrumentation and Detectors
Complementary metal-oxide-semiconductor (CMOS) detectors are a competitive choice for current and upcoming astronomical missions. To understand the performance variations of CMOS detectors in space environment, we investigate the total ionizing dose effects on custom-made large-format X-ray CMOS detectors. Three CMOS detector samples were irradiated with a Co-60 source with a total dose of 70 krad and 105 krad. We test and compare the performance of these detectors before and after irradiation. After irradiation, the dark current increases by roughly 20 to 100 times, and the readout noise increases from 3 e- to 6 e-. The bias level at 50 ms integration time decreases by 13 to 18 Digital Number (DN) at -30 degree. The energy resolution increases from about 150 eV to about 170 eV at 4.5 keV at -30 degree. The conversion gain of the detectors varies for less than 2% after the irradiation. Furthermore, there are about 50 pixels whose bias at 50 ms has changed by more than 20 DN after the exposure to the radiation and about 30 to 140 pixels whose readout noise has increased by over 20 e- at -30 degree at 50 ms integration time. These results demonstrate that the performances of large-format CMOS detectors do not suffer significant degeneration in space environment.
title Radiation Effects on Scientific CMOS Detectors for X-ray Astronomy: II. Total Ionizing Dose Irradiation
topic Instrumentation and Methods for Astrophysics
High Energy Physics - Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2403.15764