A data-based comparison of methods for reducing the peak volume flow rate in a district heating system

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Agner, Felix, Trabert, Ulrich, Rantzer, Anders, Orozaliev, Janybek
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866929287911702528
author Agner, Felix
Trabert, Ulrich
Rantzer, Anders
Orozaliev, Janybek
author_facet Agner, Felix
Trabert, Ulrich
Rantzer, Anders
Orozaliev, Janybek
contents This work concerns reduction of the peak flow rate of a district heating grid, a key system property which is bounded by pipe dimensions and pumping capacity. The peak flow rate constrains the number of additional consumers that can be connected, and may be a limiting factor in reducing supply temperatures when transitioning to the 4th generation of district heating. We evaluate a full year of operational data from a subset of customer meters in a district heating system in Germany. We consider the peak flow rate reduction that could be achieved with full a posteriori knowledge of this data. Three strategies for reducing the peak flow rate are investigated: A load shifting demand response strategy, an upper limitation in substation return temperatures, and an upper limitation on each substation's volume flow rate. We show that imposing up to to 18 % load flexibility for the customers provides an equal reduction in the peak system flow rate under the load shifting strategy. The limited return temperature strategy is less efficient at curtailing the peak flow rate, but provides an overall reduction of volume flow rates. Finally, the flow rate limitation method can introduce new, higher flow rate peaks, reducing performance.
format Preprint
id arxiv_https___arxiv_org_abs_2403_16738
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A data-based comparison of methods for reducing the peak volume flow rate in a district heating system
Agner, Felix
Trabert, Ulrich
Rantzer, Anders
Orozaliev, Janybek
Systems and Control
This work concerns reduction of the peak flow rate of a district heating grid, a key system property which is bounded by pipe dimensions and pumping capacity. The peak flow rate constrains the number of additional consumers that can be connected, and may be a limiting factor in reducing supply temperatures when transitioning to the 4th generation of district heating. We evaluate a full year of operational data from a subset of customer meters in a district heating system in Germany. We consider the peak flow rate reduction that could be achieved with full a posteriori knowledge of this data. Three strategies for reducing the peak flow rate are investigated: A load shifting demand response strategy, an upper limitation in substation return temperatures, and an upper limitation on each substation's volume flow rate. We show that imposing up to to 18 % load flexibility for the customers provides an equal reduction in the peak system flow rate under the load shifting strategy. The limited return temperature strategy is less efficient at curtailing the peak flow rate, but provides an overall reduction of volume flow rates. Finally, the flow rate limitation method can introduce new, higher flow rate peaks, reducing performance.
title A data-based comparison of methods for reducing the peak volume flow rate in a district heating system
topic Systems and Control
url https://arxiv.org/abs/2403.16738