The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Ceballos, M. Teresa, Cardiel, Nicolás, Cobo, Beatriz, Smith, Stephen J., Witthoeft, Michael C., Peille, Philippe, Durkin, Malcolm S.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910382116831232
author Ceballos, M. Teresa
Cardiel, Nicolás
Cobo, Beatriz
Smith, Stephen J.
Witthoeft, Michael C.
Peille, Philippe
Durkin, Malcolm S.
author_facet Ceballos, M. Teresa
Cardiel, Nicolás
Cobo, Beatriz
Smith, Stephen J.
Witthoeft, Michael C.
Peille, Philippe
Durkin, Malcolm S.
contents The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
format Preprint
id arxiv_https___arxiv_org_abs_2403_16965
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
Ceballos, M. Teresa
Cardiel, Nicolás
Cobo, Beatriz
Smith, Stephen J.
Witthoeft, Michael C.
Peille, Philippe
Durkin, Malcolm S.
Instrumentation and Methods for Astrophysics
The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
title The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2403.16965