WIN-PDQ: A Wiener-estimator-based projection-domain quantitative SPECT method that accounts for intra-regional uptake heterogeneity

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Li, Zekun, Benabdallah, Nadia, Thorek, Daniel L. J., Jha, Abhinav K.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866929288593276928
author Li, Zekun
Benabdallah, Nadia
Thorek, Daniel L. J.
Jha, Abhinav K.
author_facet Li, Zekun
Benabdallah, Nadia
Thorek, Daniel L. J.
Jha, Abhinav K.
contents SPECT can enable the quantification of activity uptake in lesions and at-risk organs in α-particle-emitting radiopharmaceutical therapies (α-RPTs). But this quantification is challenged by the low photon counts, complicated isotope physics, and the image-degrading effects in α-RPT SPECT. Thus, strategies to optimize the SPECT system and protocol designs for the task of regional uptake quantification are needed. Objectively performing this task-based optimization requires a reliable (accurate and precise) regional uptake quantification method. Conventional reconstruction-based quantification (RBQ) methods have been observed to be erroneous for α-RPT SPECT. Projection-domain quantification methods, which estimate regional uptake directly from SPECT projections, have demonstrated potential in providing reliable regional uptake estimates, but these methods assume constant uptake within the regions, an assumption that may not hold. To address these challenges, we propose WIN-PDQ, a Wiener-estimator-based projection-domain quantitative SPECT method. The method accounts for the heterogeneity within the regions of interest while estimating mean uptake. An early-stage evaluation of the method was conducted using 3D Monte Carlo-simulated SPECT of anthropomorphic phantoms with radium-223 uptake and lumpy-model-based intra-regional uptake heterogeneity. In this evaluation with phantoms of varying mean regional uptake and intra-regional uptake heterogeneity, the WIN-PDQ method yielded ensemble unbiased estimates and significantly outperformed both reconstruction-based and previously proposed projection-domain quantification methods. In conclusion, based on these preliminary findings, the proposed method is showing potential for estimating mean regional uptake in α-RPTs and towards enabling the objective task-based optimization of SPECT system and protocol designs.
format Preprint
id arxiv_https___arxiv_org_abs_2403_17226
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle WIN-PDQ: A Wiener-estimator-based projection-domain quantitative SPECT method that accounts for intra-regional uptake heterogeneity
Li, Zekun
Benabdallah, Nadia
Thorek, Daniel L. J.
Jha, Abhinav K.
Medical Physics
SPECT can enable the quantification of activity uptake in lesions and at-risk organs in α-particle-emitting radiopharmaceutical therapies (α-RPTs). But this quantification is challenged by the low photon counts, complicated isotope physics, and the image-degrading effects in α-RPT SPECT. Thus, strategies to optimize the SPECT system and protocol designs for the task of regional uptake quantification are needed. Objectively performing this task-based optimization requires a reliable (accurate and precise) regional uptake quantification method. Conventional reconstruction-based quantification (RBQ) methods have been observed to be erroneous for α-RPT SPECT. Projection-domain quantification methods, which estimate regional uptake directly from SPECT projections, have demonstrated potential in providing reliable regional uptake estimates, but these methods assume constant uptake within the regions, an assumption that may not hold. To address these challenges, we propose WIN-PDQ, a Wiener-estimator-based projection-domain quantitative SPECT method. The method accounts for the heterogeneity within the regions of interest while estimating mean uptake. An early-stage evaluation of the method was conducted using 3D Monte Carlo-simulated SPECT of anthropomorphic phantoms with radium-223 uptake and lumpy-model-based intra-regional uptake heterogeneity. In this evaluation with phantoms of varying mean regional uptake and intra-regional uptake heterogeneity, the WIN-PDQ method yielded ensemble unbiased estimates and significantly outperformed both reconstruction-based and previously proposed projection-domain quantification methods. In conclusion, based on these preliminary findings, the proposed method is showing potential for estimating mean regional uptake in α-RPTs and towards enabling the objective task-based optimization of SPECT system and protocol designs.
title WIN-PDQ: A Wiener-estimator-based projection-domain quantitative SPECT method that accounts for intra-regional uptake heterogeneity
topic Medical Physics
url https://arxiv.org/abs/2403.17226