Calibration of the Scintillation Timing in SNO+ using In-Situ Backgrounds

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Hunt-Stokes, Rafael
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866929294294384640
author Hunt-Stokes, Rafael
author_facet Hunt-Stokes, Rafael
contents The SNO+ Collaboration has recently concluded loading its liquid scintillator with PPO, the primary fluor, and the loading of the wavelength shifter, bisMSB, is ongoing. For each stage of the experiment, reliable position and energy reconstruction is essential, and in the face of a changing scintillator cocktail, methods have been developed to rapidly calibrate the SNO+ optical model. To this end, a novel technique for calibrating the time response of the SNO+ liquid scintillator using in-situ backgrounds was developed. By using in-situ coincident backgrounds, it is possible to calibrate both the $β^-$ and $α$ time responses, as well as facilitate frequent monitoring of the background levels without compromising the radiopurity of the detector. Accurate calibration of the liquid scintillator emission times allows the exploration of time-based particle discrimination, such as between single-site ($β^-$) and multi-site ($β^- γ$) interactions.
format Preprint
id arxiv_https___arxiv_org_abs_2403_19496
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Calibration of the Scintillation Timing in SNO+ using In-Situ Backgrounds
Hunt-Stokes, Rafael
Instrumentation and Detectors
High Energy Physics - Experiment
The SNO+ Collaboration has recently concluded loading its liquid scintillator with PPO, the primary fluor, and the loading of the wavelength shifter, bisMSB, is ongoing. For each stage of the experiment, reliable position and energy reconstruction is essential, and in the face of a changing scintillator cocktail, methods have been developed to rapidly calibrate the SNO+ optical model. To this end, a novel technique for calibrating the time response of the SNO+ liquid scintillator using in-situ backgrounds was developed. By using in-situ coincident backgrounds, it is possible to calibrate both the $β^-$ and $α$ time responses, as well as facilitate frequent monitoring of the background levels without compromising the radiopurity of the detector. Accurate calibration of the liquid scintillator emission times allows the exploration of time-based particle discrimination, such as between single-site ($β^-$) and multi-site ($β^- γ$) interactions.
title Calibration of the Scintillation Timing in SNO+ using In-Situ Backgrounds
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2403.19496