Enhancing interferometry using weak value amplification with real weak values

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Huang, Jing-Hui, Jordan, Kyle M., Dada, Adetunmise C., Hu, Xiang-Yun, Lundeen, Jeff. S.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913711633989632
author Huang, Jing-Hui
Jordan, Kyle M.
Dada, Adetunmise C.
Hu, Xiang-Yun
Lundeen, Jeff. S.
author_facet Huang, Jing-Hui
Jordan, Kyle M.
Dada, Adetunmise C.
Hu, Xiang-Yun
Lundeen, Jeff. S.
contents We introduce an ultra-sensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA + interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors, {but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise}. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultra-sensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrowband light using real weak values.
format Preprint
id arxiv_https___arxiv_org_abs_2404_00531
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Enhancing interferometry using weak value amplification with real weak values
Huang, Jing-Hui
Jordan, Kyle M.
Dada, Adetunmise C.
Hu, Xiang-Yun
Lundeen, Jeff. S.
Quantum Physics
We introduce an ultra-sensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA + interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors, {but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise}. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultra-sensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrowband light using real weak values.
title Enhancing interferometry using weak value amplification with real weak values
topic Quantum Physics
url https://arxiv.org/abs/2404.00531