contents This paper discusses the stability assessment of low-inertia power systems through a real-world large-scale low-inertia system, namely, the All-Island power system (AIPS) of Ireland and Northern Ireland. This system currently accommodates world-record levels of system non-synchronous penetration namely 75% (planning to increase to 80% next year). The paper discusses one-month results obtained with the state-of-the-art stability tool called look-ahead security assessment (LSAT). This tool carries out rotor-angle, frequency and voltage stability analyses and is implemented in the control centres of the transmission system operators (TSOs). The paper shows that, at the time of writing, the main binding stability constraint of the AIPS is related to the limits on the rate of change of frequency (RoCoF).
format Preprint
id arxiv_https___arxiv_org_abs_2404_04618
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Stability Assessment of Low-Inertia Power Systems: A System Operator Perspective
Hurtado, Manuel
Jafarian, Mohammad
Kerci, Taulant
Tweed, Simon
Escudero, Marta Val
Kennedy, Eoin
Milano, Federico
Systems and Control
This paper discusses the stability assessment of low-inertia power systems through a real-world large-scale low-inertia system, namely, the All-Island power system (AIPS) of Ireland and Northern Ireland. This system currently accommodates world-record levels of system non-synchronous penetration namely 75% (planning to increase to 80% next year). The paper discusses one-month results obtained with the state-of-the-art stability tool called look-ahead security assessment (LSAT). This tool carries out rotor-angle, frequency and voltage stability analyses and is implemented in the control centres of the transmission system operators (TSOs). The paper shows that, at the time of writing, the main binding stability constraint of the AIPS is related to the limits on the rate of change of frequency (RoCoF).
title Stability Assessment of Low-Inertia Power Systems: A System Operator Perspective
topic Systems and Control
url https://arxiv.org/abs/2404.04618