8x8 Patch-Antenna-Coupled TeraFET Detector Array for Terahertz Quantum-Cascade-Laser Applications

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Holstein, Jakob, North, Nicholas K., Horbury, Michael D., Kondawar, Sanchit, Kundu, Imon, Salih, Mohammed, Krysl, Anastasiya, Li, Lianhe, Linfield, Edmund H., Freeman, Joshua R., Valavanis, Alexander, Lisauskas, Alvydas, Roskos, Hartmut G.
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866929448202272768
author Holstein, Jakob
North, Nicholas K.
Horbury, Michael D.
Kondawar, Sanchit
Kundu, Imon
Salih, Mohammed
Krysl, Anastasiya
Li, Lianhe
Linfield, Edmund H.
Freeman, Joshua R.
Valavanis, Alexander
Lisauskas, Alvydas
Roskos, Hartmut G.
author_facet Holstein, Jakob
North, Nicholas K.
Horbury, Michael D.
Kondawar, Sanchit
Kundu, Imon
Salih, Mohammed
Krysl, Anastasiya
Li, Lianhe
Linfield, Edmund H.
Freeman, Joshua R.
Valavanis, Alexander
Lisauskas, Alvydas
Roskos, Hartmut G.
contents Monolithically integrated, antenna-coupled field-effect transistors (TeraFETs) are rapid and sensitive detectors for the terahertz range (0.3-10~THz) that can operate at room temperature. We conducted experimental characterizations of a single patch-antenna coupled TeraFET optimized for 3.4~THz operation and its integration into an 8x8 multi-element detector configuration. In this configuration, the entire TeraFET array operates as a unified detector element, combining the output signals of all detector elements. Both detectors were realized using a mature commercial Si-CMOS 65-nm process node. Our experimental characterization employed single-mode Quantum-Cascade Lasers (QCLs) emitting at 2.85~THz and 3.4~THz. The 8x8 multi-element detector yields two major improvements for sensitive power detection experiments. First, the larger detector area simplifies alignment and enhances signal stability. Second, the reduced detector impedance enabled the implementation of a TeraFET+QCL system capable of providing a -3~dB modulation bandwidth up to 21~MHz, which is currently limited primarily by the chosen readout circuitry. Finally, we validate the system's performance by providing high resolution gas spectroscopy data for methanol vapor around 3.4~THz, where a detection limit of 1.6e-5 absorbance, or 2.6e11~molecules/cm^3 was estimated under optimal coupling conditions.
format Preprint
id arxiv_https___arxiv_org_abs_2404_07309
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle 8x8 Patch-Antenna-Coupled TeraFET Detector Array for Terahertz Quantum-Cascade-Laser Applications
Holstein, Jakob
North, Nicholas K.
Horbury, Michael D.
Kondawar, Sanchit
Kundu, Imon
Salih, Mohammed
Krysl, Anastasiya
Li, Lianhe
Linfield, Edmund H.
Freeman, Joshua R.
Valavanis, Alexander
Lisauskas, Alvydas
Roskos, Hartmut G.
Instrumentation and Detectors
Monolithically integrated, antenna-coupled field-effect transistors (TeraFETs) are rapid and sensitive detectors for the terahertz range (0.3-10~THz) that can operate at room temperature. We conducted experimental characterizations of a single patch-antenna coupled TeraFET optimized for 3.4~THz operation and its integration into an 8x8 multi-element detector configuration. In this configuration, the entire TeraFET array operates as a unified detector element, combining the output signals of all detector elements. Both detectors were realized using a mature commercial Si-CMOS 65-nm process node. Our experimental characterization employed single-mode Quantum-Cascade Lasers (QCLs) emitting at 2.85~THz and 3.4~THz. The 8x8 multi-element detector yields two major improvements for sensitive power detection experiments. First, the larger detector area simplifies alignment and enhances signal stability. Second, the reduced detector impedance enabled the implementation of a TeraFET+QCL system capable of providing a -3~dB modulation bandwidth up to 21~MHz, which is currently limited primarily by the chosen readout circuitry. Finally, we validate the system's performance by providing high resolution gas spectroscopy data for methanol vapor around 3.4~THz, where a detection limit of 1.6e-5 absorbance, or 2.6e11~molecules/cm^3 was estimated under optimal coupling conditions.
title 8x8 Patch-Antenna-Coupled TeraFET Detector Array for Terahertz Quantum-Cascade-Laser Applications
topic Instrumentation and Detectors
url https://arxiv.org/abs/2404.07309