Novel Method to Estimate Kinetic Microparameters from Dynamic Whole-Body Imaging in Regular-Axial Field-of-View PET Scanners

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Lee, Kyung-Nam, Rahmim, Arman, Uribe, Carlos
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866916242623823872
author Lee, Kyung-Nam
Rahmim, Arman
Uribe, Carlos
author_facet Lee, Kyung-Nam
Rahmim, Arman
Uribe, Carlos
contents For whole-body (WB) kinetic modeling based on a typical PET scanner, a multi-pass multi-bed scanning protocol is necessary given the limited axial field-of-view. Such a protocol introduces loss of early-dynamics in time-activity curves (TACs) and sparsity in TAC measurements, inducing uncertainty in parameter estimation when using least-squares estimation (LSE) (i.e., common standard) especially for kinetic microparameters. We present a method to reliably estimate microparameters, enabling accurate parametric imaging, on regular-axial field-of-view PET scanners. Our method, denoted parameter combination-driven estimation (PCDE), relies on generation of reference truth TAC database, and subsequently selecting, the best parameter combination as the one arriving at TAC with highest total similarity score (TSS), focusing on general image quality, overall visibility, and tumor detectability metrics. Our technique has two distinctive characteristics: 1) improved probability of having one-on-one mapping between early and late dynamics in TACs (the former missing from typical protocols), and 2) use of multiple aspects of TACs in selection of best fits. To evaluate our method against conventional LSE, we plotted tradeoff curves for noise and bias. In addition, the overall SNR and spatial noise were calculated and compared. Furthermore, CNR and TBR were also calculated. We also tested our proposed method on patient data (18F-DCFPyL PET scans) to further verify clinical applicability. Significantly improved general image quality performance was verified in microparametric images (e.g. noise-bias performance). The overall visibility and tumor detectability were also improved. Finally, for our patient studies, improved overall visibility and tumor detectability were demonstrated in micoparametric images, compared to use of conventional parameter estimation.
format Preprint
id arxiv_https___arxiv_org_abs_2404_10197
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Novel Method to Estimate Kinetic Microparameters from Dynamic Whole-Body Imaging in Regular-Axial Field-of-View PET Scanners
Lee, Kyung-Nam
Rahmim, Arman
Uribe, Carlos
Medical Physics
For whole-body (WB) kinetic modeling based on a typical PET scanner, a multi-pass multi-bed scanning protocol is necessary given the limited axial field-of-view. Such a protocol introduces loss of early-dynamics in time-activity curves (TACs) and sparsity in TAC measurements, inducing uncertainty in parameter estimation when using least-squares estimation (LSE) (i.e., common standard) especially for kinetic microparameters. We present a method to reliably estimate microparameters, enabling accurate parametric imaging, on regular-axial field-of-view PET scanners. Our method, denoted parameter combination-driven estimation (PCDE), relies on generation of reference truth TAC database, and subsequently selecting, the best parameter combination as the one arriving at TAC with highest total similarity score (TSS), focusing on general image quality, overall visibility, and tumor detectability metrics. Our technique has two distinctive characteristics: 1) improved probability of having one-on-one mapping between early and late dynamics in TACs (the former missing from typical protocols), and 2) use of multiple aspects of TACs in selection of best fits. To evaluate our method against conventional LSE, we plotted tradeoff curves for noise and bias. In addition, the overall SNR and spatial noise were calculated and compared. Furthermore, CNR and TBR were also calculated. We also tested our proposed method on patient data (18F-DCFPyL PET scans) to further verify clinical applicability. Significantly improved general image quality performance was verified in microparametric images (e.g. noise-bias performance). The overall visibility and tumor detectability were also improved. Finally, for our patient studies, improved overall visibility and tumor detectability were demonstrated in micoparametric images, compared to use of conventional parameter estimation.
title Novel Method to Estimate Kinetic Microparameters from Dynamic Whole-Body Imaging in Regular-Axial Field-of-View PET Scanners
topic Medical Physics
url https://arxiv.org/abs/2404.10197