Spectroscopic measurements and models of energy deposition in the substrate of quantum circuits by natural ionizing radiation

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Fowler, Joseph W., Szypryt, Paul, Bunker, Raymond, Edwards, Ellen R., Florang, Ian Fogarty, Gao, Jiansong, Giachero, Andrea, Hoogerheide, Shannon F., Loer, Ben, Mumm, H. Pieter, Nakamura, Nathan, O'Neil, Galen C., Orrell, John L., Scott, Elizabeth M., Stevens, Jason, Swetz, Daniel S., VanDevender, Brent A., Vissers, Michael, Ullom, Joel N.
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866910694830505984
author Fowler, Joseph W.
Szypryt, Paul
Bunker, Raymond
Edwards, Ellen R.
Florang, Ian Fogarty
Gao, Jiansong
Giachero, Andrea
Hoogerheide, Shannon F.
Loer, Ben
Mumm, H. Pieter
Nakamura, Nathan
O'Neil, Galen C.
Orrell, John L.
Scott, Elizabeth M.
Stevens, Jason
Swetz, Daniel S.
VanDevender, Brent A.
Vissers, Michael
Ullom, Joel N.
author_facet Fowler, Joseph W.
Szypryt, Paul
Bunker, Raymond
Edwards, Ellen R.
Florang, Ian Fogarty
Gao, Jiansong
Giachero, Andrea
Hoogerheide, Shannon F.
Loer, Ben
Mumm, H. Pieter
Nakamura, Nathan
O'Neil, Galen C.
Orrell, John L.
Scott, Elizabeth M.
Stevens, Jason
Swetz, Daniel S.
VanDevender, Brent A.
Vissers, Michael
Ullom, Joel N.
contents Naturally occurring background radiation is a source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. To characterize the radiation environment in an unshielded laboratory, we performed broadband, spectroscopic measurements of background events in silicon substrates located inside a millikelvin refrigerator, an environment representative of superconducting qubit systems. We measured the background spectra in silicon substrates of two thicknesses, 0.5 mm and 1.5 mm, and obtained the average event rate and the integrated power deposition. In a 25 mm^2 area and the thinner substrate, these values are 0.023 events per second and 4.9 keV/s, counting events that deposit at least 40 keV. We find the background spectrum to be nearly featureless. Its intensity decreases by a factor of 40,000 between 100 keV and 3 MeV for silicon substrates 0.5 mm thick. We find the cryogenic measurements to be in good agreement with predictions based on measurements of the terrestrial gamma-ray flux, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. No free parameters are required to predict the background spectra in the silicon substrates. The good agreement between measurements and predictions allow assessment of the relative contributions of terrestrial and cosmic background sources and their dependence on substrate thickness. Our spectroscopic measurements are performed with superconducting microresonators that transduce deposited energy to a readily detectable electrical signal. We find that gamma-ray emissions from radioisotopes are responsible for the majority of events depositing E<1.5 MeV, while nucleons among the cosmic-ray secondary particles cause most events that deposit more energy. These results suggest several paths to reducing the impact of background radiation on quantum circuits.
format Preprint
id arxiv_https___arxiv_org_abs_2404_10866
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Spectroscopic measurements and models of energy deposition in the substrate of quantum circuits by natural ionizing radiation
Fowler, Joseph W.
Szypryt, Paul
Bunker, Raymond
Edwards, Ellen R.
Florang, Ian Fogarty
Gao, Jiansong
Giachero, Andrea
Hoogerheide, Shannon F.
Loer, Ben
Mumm, H. Pieter
Nakamura, Nathan
O'Neil, Galen C.
Orrell, John L.
Scott, Elizabeth M.
Stevens, Jason
Swetz, Daniel S.
VanDevender, Brent A.
Vissers, Michael
Ullom, Joel N.
Quantum Physics
Instrumentation and Detectors
Naturally occurring background radiation is a source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. To characterize the radiation environment in an unshielded laboratory, we performed broadband, spectroscopic measurements of background events in silicon substrates located inside a millikelvin refrigerator, an environment representative of superconducting qubit systems. We measured the background spectra in silicon substrates of two thicknesses, 0.5 mm and 1.5 mm, and obtained the average event rate and the integrated power deposition. In a 25 mm^2 area and the thinner substrate, these values are 0.023 events per second and 4.9 keV/s, counting events that deposit at least 40 keV. We find the background spectrum to be nearly featureless. Its intensity decreases by a factor of 40,000 between 100 keV and 3 MeV for silicon substrates 0.5 mm thick. We find the cryogenic measurements to be in good agreement with predictions based on measurements of the terrestrial gamma-ray flux, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. No free parameters are required to predict the background spectra in the silicon substrates. The good agreement between measurements and predictions allow assessment of the relative contributions of terrestrial and cosmic background sources and their dependence on substrate thickness. Our spectroscopic measurements are performed with superconducting microresonators that transduce deposited energy to a readily detectable electrical signal. We find that gamma-ray emissions from radioisotopes are responsible for the majority of events depositing E<1.5 MeV, while nucleons among the cosmic-ray secondary particles cause most events that deposit more energy. These results suggest several paths to reducing the impact of background radiation on quantum circuits.
title Spectroscopic measurements and models of energy deposition in the substrate of quantum circuits by natural ionizing radiation
topic Quantum Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2404.10866