Direct Comparison of SiPM and PMT Sensor Performances in a large-size imaging air Cherenkov telescope

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Hahn, A., Mirzoyan, R., Dettlaff, A., Fink, D., Mazin, D., Teshima, M.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866911849064169472
author Hahn, A.
Mirzoyan, R.
Dettlaff, A.
Fink, D.
Mazin, D.
Teshima, M.
author_facet Hahn, A.
Mirzoyan, R.
Dettlaff, A.
Fink, D.
Mazin, D.
Teshima, M.
contents The peak photon detection efficiency (PDE) of silicon photomultipliers (SiPMs) can be as good or better than the PDE of photomultiplier tubes (PMTs). There are experiments where the signal is measured in the presence of a strong, steady background light emission. In these, one needs to accurately evaluate the signal-to-noise ratio. Imaging Atmospheric Cherenkov Telescopes (IACTs) observe in the presence of strong noise induced by the light of the night sky. It is certainly interesting to investigate the SiPM performance under operational conditions of IACTs and to compare it with that of the PMTs. For that purpose, we built a SiPM-based detector module, which was installed in one of the imaging cameras of the two Major Atmospheric Gamma-ray Imaging Cherenkov (MAGIC) telescopes in 2015. The experience gained from that module was used to design the second generation of modules of improved performance. Two such modules were installed in 2017. MAGIC is a system of two IACTs located on the Canary Island of La Palma. The mechanical structure of the MAGIC imaging cameras offers the possibility to install up to 6 additional detector modules of 7 pixels each into the open vertices of the hexagonal-shaped camera. This allows us to directly, without making any assumption, compare the performance of the PMT-based modules with that of the SiPM-based prototype modules, where SiPMs from three different manufacturers are used.
format Preprint
id arxiv_https___arxiv_org_abs_2404_14346
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Direct Comparison of SiPM and PMT Sensor Performances in a large-size imaging air Cherenkov telescope
Hahn, A.
Mirzoyan, R.
Dettlaff, A.
Fink, D.
Mazin, D.
Teshima, M.
Instrumentation and Methods for Astrophysics
The peak photon detection efficiency (PDE) of silicon photomultipliers (SiPMs) can be as good or better than the PDE of photomultiplier tubes (PMTs). There are experiments where the signal is measured in the presence of a strong, steady background light emission. In these, one needs to accurately evaluate the signal-to-noise ratio. Imaging Atmospheric Cherenkov Telescopes (IACTs) observe in the presence of strong noise induced by the light of the night sky. It is certainly interesting to investigate the SiPM performance under operational conditions of IACTs and to compare it with that of the PMTs. For that purpose, we built a SiPM-based detector module, which was installed in one of the imaging cameras of the two Major Atmospheric Gamma-ray Imaging Cherenkov (MAGIC) telescopes in 2015. The experience gained from that module was used to design the second generation of modules of improved performance. Two such modules were installed in 2017. MAGIC is a system of two IACTs located on the Canary Island of La Palma. The mechanical structure of the MAGIC imaging cameras offers the possibility to install up to 6 additional detector modules of 7 pixels each into the open vertices of the hexagonal-shaped camera. This allows us to directly, without making any assumption, compare the performance of the PMT-based modules with that of the SiPM-based prototype modules, where SiPMs from three different manufacturers are used.
title Direct Comparison of SiPM and PMT Sensor Performances in a large-size imaging air Cherenkov telescope
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2404.14346