Jitter Characterization of the HyTI Satellite

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Urasaki, Chase, Zhu, Frances, Bottom, Michael, Nunes, Miguel, Walk, Aidan
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866916220819734528
author Urasaki, Chase
Zhu, Frances
Bottom, Michael
Nunes, Miguel
Walk, Aidan
author_facet Urasaki, Chase
Zhu, Frances
Bottom, Michael
Nunes, Miguel
Walk, Aidan
contents The Hyperspectral Thermal Imager (HyTI) is a technology demonstration mission that will obtain high spatial, spectral, and temporal resolution long-wave infrared images of Earth's surface from a 6U cubesat. HyTI science requires that the pointing accuracy of the optical axis shall not exceed 2.89 arcsec over the 0.5 ms integration time due to microvibration effects (known as jitter). Two sources of vibration are a cryocooler that is added to maintain the detector at 68 K and three orthogonally placed reaction wheels that are a part of the attitude control system. Both of these parts will introduce vibrations that are propagated through to the satellite structure while imaging. Typical methods of characterizing and measuring jitter involve complex finite element methods and specialized equipment and setups. In this paper, we describe a novel method of characterizing jitter for small satellite systems that is low-cost and minimally modifies the subject's mass distribution. The metrology instrument is comprised of a laser source, a small mirror mounted via a 3D printed clamp to a jig, and a lateral effect position-sensing detector. The position-sensing detector samples 1000 Hz and can measure displacements as little as 0.15 arcsec at distances of one meter. This paper provides an experimental procedure that incrementally analyzes vibratory sources to establish causal relationships between sources and the vibratory modes they create. We demonstrate the capabilities of this metrology system and testing procedure on HyTI in the Hawaii Space Flight Lab's clean room. Results include power spectral density plots that show fundamental and higher-order vibratory modal frequencies. Results from metrology show that jitter from reaction wheels meets HyTI system requirements within 3$σ$.
format Preprint
id arxiv_https___arxiv_org_abs_2404_15575
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Jitter Characterization of the HyTI Satellite
Urasaki, Chase
Zhu, Frances
Bottom, Michael
Nunes, Miguel
Walk, Aidan
Instrumentation and Methods for Astrophysics
Systems and Control
The Hyperspectral Thermal Imager (HyTI) is a technology demonstration mission that will obtain high spatial, spectral, and temporal resolution long-wave infrared images of Earth's surface from a 6U cubesat. HyTI science requires that the pointing accuracy of the optical axis shall not exceed 2.89 arcsec over the 0.5 ms integration time due to microvibration effects (known as jitter). Two sources of vibration are a cryocooler that is added to maintain the detector at 68 K and three orthogonally placed reaction wheels that are a part of the attitude control system. Both of these parts will introduce vibrations that are propagated through to the satellite structure while imaging. Typical methods of characterizing and measuring jitter involve complex finite element methods and specialized equipment and setups. In this paper, we describe a novel method of characterizing jitter for small satellite systems that is low-cost and minimally modifies the subject's mass distribution. The metrology instrument is comprised of a laser source, a small mirror mounted via a 3D printed clamp to a jig, and a lateral effect position-sensing detector. The position-sensing detector samples 1000 Hz and can measure displacements as little as 0.15 arcsec at distances of one meter. This paper provides an experimental procedure that incrementally analyzes vibratory sources to establish causal relationships between sources and the vibratory modes they create. We demonstrate the capabilities of this metrology system and testing procedure on HyTI in the Hawaii Space Flight Lab's clean room. Results include power spectral density plots that show fundamental and higher-order vibratory modal frequencies. Results from metrology show that jitter from reaction wheels meets HyTI system requirements within 3$σ$.
title Jitter Characterization of the HyTI Satellite
topic Instrumentation and Methods for Astrophysics
Systems and Control
url https://arxiv.org/abs/2404.15575