Reciprocity in laser ultrasound revisited: Is wavefield characterisation by scanning laser excitation strictly reciprocal to that by scanning laser detection?

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Köhler, Bernd, Amano, Yuui, Schubert, Frank, Nakahata, Kazuyuki
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866909971292094464
author Köhler, Bernd
Amano, Yuui
Schubert, Frank
Nakahata, Kazuyuki
author_facet Köhler, Bernd
Amano, Yuui
Schubert, Frank
Nakahata, Kazuyuki
contents The common believe about strict measurement reciprocity between scanning laser detection and scanning laser excitation is disproved by a simple experiment. Nevertheless, a deeper study based on the reciprocity relation reveals correct reciprocal measurement set-ups for both the probe-excitation / laser-detection and the laser-excitation / probe-detection case. Similarly, the all-laser measurement, that is thermoelastic laser excitation with laser vibrometer detection, is not in general reciprocal with respect to the exchange of excitation and detection positions. Again, a substitute for the laser doppler vibrometer out-of-plane displacement measurement was found which ensures measurement reciprocity together with laser excitation. The apparent confusion in literature about strict validity/non-validity of measurement reciprocity is mitigated by classifying the measurement situations systematically.
format Preprint
id arxiv_https___arxiv_org_abs_2404_16424
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Reciprocity in laser ultrasound revisited: Is wavefield characterisation by scanning laser excitation strictly reciprocal to that by scanning laser detection?
Köhler, Bernd
Amano, Yuui
Schubert, Frank
Nakahata, Kazuyuki
Instrumentation and Detectors
Systems and Control
Optics
The common believe about strict measurement reciprocity between scanning laser detection and scanning laser excitation is disproved by a simple experiment. Nevertheless, a deeper study based on the reciprocity relation reveals correct reciprocal measurement set-ups for both the probe-excitation / laser-detection and the laser-excitation / probe-detection case. Similarly, the all-laser measurement, that is thermoelastic laser excitation with laser vibrometer detection, is not in general reciprocal with respect to the exchange of excitation and detection positions. Again, a substitute for the laser doppler vibrometer out-of-plane displacement measurement was found which ensures measurement reciprocity together with laser excitation. The apparent confusion in literature about strict validity/non-validity of measurement reciprocity is mitigated by classifying the measurement situations systematically.
title Reciprocity in laser ultrasound revisited: Is wavefield characterisation by scanning laser excitation strictly reciprocal to that by scanning laser detection?
topic Instrumentation and Detectors
Systems and Control
Optics
url https://arxiv.org/abs/2404.16424