contents In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify Bhabha scattering at low polar angles. Usually, such a device is placed at the outgoing beams, to keep the spatial symmetries of the head-on collisions at accelerators with a non-zero crossing angle. At CEPC it is currently proposed to place the luminometer on the z-axis. We review a feasibility of a measurement of the integrated luminosity at the $Z^{0}$ pole with the required precision, concerning the luminometer centered around the z-axis and the post-CDR beam properties.
format Preprint
id arxiv_https___arxiv_org_abs_2404_18605
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Uncertainties from metrology in the integrated luminosity measurement with the updated design of a detector at CEPC
Smiljanic, Ivan
Bozovic, Ivanka
Kacarevic, Goran
High Energy Physics - Experiment
Instrumentation and Detectors
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify Bhabha scattering at low polar angles. Usually, such a device is placed at the outgoing beams, to keep the spatial symmetries of the head-on collisions at accelerators with a non-zero crossing angle. At CEPC it is currently proposed to place the luminometer on the z-axis. We review a feasibility of a measurement of the integrated luminosity at the $Z^{0}$ pole with the required precision, concerning the luminometer centered around the z-axis and the post-CDR beam properties.
title Uncertainties from metrology in the integrated luminosity measurement with the updated design of a detector at CEPC
topic High Energy Physics - Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2404.18605