Optimization of Dark-Field CT for Lung Imaging

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Guo, Peiyuan, Spindler, Simon, Zhang, Li, Wang, Zhentian
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929333313994752
author Guo, Peiyuan
Spindler, Simon
Zhang, Li
Wang, Zhentian
author_facet Guo, Peiyuan
Spindler, Simon
Zhang, Li
Wang, Zhentian
contents Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by an object's micro-structure. This technique is sensitive to lung's porous alveoli and is able to detect lung disease at an early stage. Up to now, a human-scale dark-field CT has been built for lung imaging. Purpose: This study aimed to develop a more thorough optimization method for dark-field lung CT and summarize principles for system design. Methods: We proposed a metric in the form of contrast-to-noise ratio (CNR) for system parameter optimization, and designed a phantom with concentric circle shape to fit the task of lung disease detection. Finally, we developed the calculation method of the CNR metric, and analyzed the relation between CNR and system parameters. Results: We showed that with other parameters held constant, the CNR first increases and then decreases with the system auto-correlation length (ACL). The optimal ACL is nearly not influenced by system's visibility, and is only related to phantom's property, i.e., scattering material's size and phantom's absorption. For our phantom, the optimal ACL is about 0.21 μm. As for system geometry, larger source-detector and isocenter-detector distance can increase the system's maximal ACL, helping the system meet the optimal ACL more easily. Conclusions: This study proposed a more reasonable metric and a task-based process for optimization, and demonstrated that the system optimal ACL is only related to the phantom's property.
format Preprint
id arxiv_https___arxiv_org_abs_2405_00259
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Optimization of Dark-Field CT for Lung Imaging
Guo, Peiyuan
Spindler, Simon
Zhang, Li
Wang, Zhentian
Medical Physics
Image and Video Processing
Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by an object's micro-structure. This technique is sensitive to lung's porous alveoli and is able to detect lung disease at an early stage. Up to now, a human-scale dark-field CT has been built for lung imaging. Purpose: This study aimed to develop a more thorough optimization method for dark-field lung CT and summarize principles for system design. Methods: We proposed a metric in the form of contrast-to-noise ratio (CNR) for system parameter optimization, and designed a phantom with concentric circle shape to fit the task of lung disease detection. Finally, we developed the calculation method of the CNR metric, and analyzed the relation between CNR and system parameters. Results: We showed that with other parameters held constant, the CNR first increases and then decreases with the system auto-correlation length (ACL). The optimal ACL is nearly not influenced by system's visibility, and is only related to phantom's property, i.e., scattering material's size and phantom's absorption. For our phantom, the optimal ACL is about 0.21 μm. As for system geometry, larger source-detector and isocenter-detector distance can increase the system's maximal ACL, helping the system meet the optimal ACL more easily. Conclusions: This study proposed a more reasonable metric and a task-based process for optimization, and demonstrated that the system optimal ACL is only related to the phantom's property.
title Optimization of Dark-Field CT for Lung Imaging
topic Medical Physics
Image and Video Processing
url https://arxiv.org/abs/2405.00259