Baseline Drift Tolerant Signal Encoding for ECG Classification with Deep Learning

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Shea, Robert O, Katti, Prabodh, Rajendran, Bipin
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866916231860191232
author Shea, Robert O
Katti, Prabodh
Rajendran, Bipin
author_facet Shea, Robert O
Katti, Prabodh
Rajendran, Bipin
contents Common artefacts such as baseline drift, rescaling, and noise critically limit the performance of machine learningbased automated ECG analysis and interpretation. This study proposes Derived Peak (DP) encoding, a non-parametric method that generates signed spikes corresponding to zero crossings of the signals first and second-order time derivatives. Notably, DP encoding is invariant to shift and scaling artefacts, and its implementation is further simplified by the absence of userdefined parameters. DP encoding was used to encode the 12-lead ECG data from the PTB-XL dataset (n=18,869 participants) and was fed to 1D-ResNet-18 models trained to identify myocardial infarction, conductive deficits and ST-segment abnormalities. Robustness to artefacts was assessed by corrupting ECG data with sinusoidal baseline drift, shift, rescaling and noise, before encoding. The addition of these artefacts resulted in a significant drop in accuracy for seven other methods from prior art, while DP encoding maintained a baseline AUC of 0.88 under drift, shift and rescaling. DP achieved superior performance to unencoded inputs in the presence of shift (AUC under 1mV shift: 0.91 vs 0.62), and rescaling artefacts (AUC 0.91 vs 0.79). Thus, DP encoding is a simple method by which robustness to common ECG artefacts may be improved for automated ECG analysis and interpretation.
format Preprint
id arxiv_https___arxiv_org_abs_2405_00724
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Baseline Drift Tolerant Signal Encoding for ECG Classification with Deep Learning
Shea, Robert O
Katti, Prabodh
Rajendran, Bipin
Signal Processing
Machine Learning
I.5.4
Common artefacts such as baseline drift, rescaling, and noise critically limit the performance of machine learningbased automated ECG analysis and interpretation. This study proposes Derived Peak (DP) encoding, a non-parametric method that generates signed spikes corresponding to zero crossings of the signals first and second-order time derivatives. Notably, DP encoding is invariant to shift and scaling artefacts, and its implementation is further simplified by the absence of userdefined parameters. DP encoding was used to encode the 12-lead ECG data from the PTB-XL dataset (n=18,869 participants) and was fed to 1D-ResNet-18 models trained to identify myocardial infarction, conductive deficits and ST-segment abnormalities. Robustness to artefacts was assessed by corrupting ECG data with sinusoidal baseline drift, shift, rescaling and noise, before encoding. The addition of these artefacts resulted in a significant drop in accuracy for seven other methods from prior art, while DP encoding maintained a baseline AUC of 0.88 under drift, shift and rescaling. DP achieved superior performance to unencoded inputs in the presence of shift (AUC under 1mV shift: 0.91 vs 0.62), and rescaling artefacts (AUC 0.91 vs 0.79). Thus, DP encoding is a simple method by which robustness to common ECG artefacts may be improved for automated ECG analysis and interpretation.
title Baseline Drift Tolerant Signal Encoding for ECG Classification with Deep Learning
topic Signal Processing
Machine Learning
I.5.4
url https://arxiv.org/abs/2405.00724